PCM fiber results lab report, NYC Law Department, Feb 2002

Machine-extracted title · confidence 90%

Laboratory report documenting polarized light microscopy fiber analysis results for OSHA compliance air samples submitted to the NYC Law Department.

NYC-WTC_000174351
Page image
Scanned page image, NYC-WTC_000174351
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Sci b#; 202022291 Pa of 1 Client Name: TRC Environmental Corporation Phase Contrast Microscopy (PCM) Fiber Results 35052-0000-00007; NYC Law Dept; 100 Church Street, OSHA Flow Air Fiber Fibers SciLab Client Rate Duration Filtered Density Cone. Fields Fibers TWA Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)

01 GS-OSHA-21302-0603 2/13/02 2 300 600 100 20 25.48 0.016 Mike Green 02 GS-OSHA-21302-0604 2/13/02 2 300 600 100 43 54.78 0.035 Manolo Ailes Footnotes: 1 03 GS-OSHA-21302-0605 2/13/02 2 240 480 100 23 29.30 0.024 Mike Green 04 GS-OSHA-21302-0606 2/13/02 2 240 480 100 1 1.27 <0.006 Manolo Ailes 05 GS-OSHA-21302-0607 2/13/02 0 0 0 100 0.5 0.64 Blank Footnotes: 2 06 GS-OSHA-21302-0608 2/13/02 0 0 0 100 0.5 0.64 Blank Footnotes; 2 Reporting Notes: (1) Moderate to heavy particulate matter is present on the fdter which may obscure some fibers causing results with a low bias. (2) Fibers/cc cannot for sam^s (or blanks) with no air volume. Analyzed by; Marvin Brother.v'J 1) \: Date Analyzed; 2/14/02 Samples analyzed by NIOSH 7400(A) xisflwd, Issue #2, 8/15/94; Limit of Detections 5.5 fibers per 100 fields or 7 fibeis/nini2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filler area; ND=No fibers observed: NA= Not Analyzed; Walton-Beckett graticle field area = 0.00785 mm2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled; Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to determine 95% certainty of compliance with the 0.01 fiber/cc standard; Estimated relative standard deviation; Iniralab Sr=0.4(15, Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480); National Institute of Standards and Technology Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.

o H

to S o o o I o to cn cn

co

NYC-WTC_000174351

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000174351Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →