SciLa #: 202022292 Pag of 1
Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; NYC Law Dept.; 100 Church Street, OSHA
Flow Air Fiber Fibers
SciLab Client Rate Duration Filtered Density Cone. TWA
Fields Fibers
Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-STEL-21302-0602 2/13/02 2 30 60 too 50 63.69 0.409
Mike Green Footnotes: /
02 GS-STEL-21302-0603 2/13/02 2 30 60 100 18 22.93 0.147
Manolo Ailes
03 GS-STEL-21302-0604 2/13/02 0 0 0 100 0.5 0.64
Blank Footnotes: 2
04 GS-STEL-21302-0605 2/13/02 0 0 0 100 0.5 0.64
Blank Footnotes: 2
Reporting Notes:
(1) Moderate to heavy particulate matter is present on the filter which may obscure some fibers causing results with a low bias.
(2) Fibers/cc cannot be/clJ^l^jfor samp^(or blanks) with no air volume.
Analyzed by; Marvin Brothers tl ' ' ; Date Analyzed; 2/14/02
Samples analyzed by NIOSH 74(X)(A) Method, Issue #2. 8/15/94; Limit of Detection= 5.5 fibers per 100 fields or 7 fibers/iniii2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: ND=No fibers observed: NA= Not
Analyzed; Walton-Beckett graticle field area = 0.00785 mm2; TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation: Intralab Sr=0.405. Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology
Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.