NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
t New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 10/11/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method AHERA Final Rule, EPA Federal Register (40 CFR, Part 763!, Vol 52, No 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site. 99 Church Street, 99 Church St , NY, NY TEM Sample No 5660 60863
Sth Floor
Date Received 10/10/01 Grid Openings Analyzed:__ 4
Project Sample No. 8-2 Average Grid Opening: 106 00 um
Air Volume 1800 liters Total Area Analyzed 0 0450 mni2
Filter Type MCE 25 mm diam , Pore Size 045 um Analytical Sensitivity 22 2 s/mm2
Effective Area 385 mm2 0 0048 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total Struct Filter Air
Fibers Bundles Clusters Struct Struct >=5um Struct/mm2 Struct/cG ngm/in3
Chrysotile Asbestos 0 0 0 0 0 0 0 0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0 0 0 0000 0
Ambiguous 0 0 0 0 0 0 0 0 0 0000 0
Total asbestos (includes ambiguous structures) 0 0 0 0 0 0000 0
Non-Asbestos 0 0 0 0 0 0 0 0 0 0000 N/A
No Identification 0 0 0 0 0 0 0 0 0.0000 N/A
Totals (All Structures) 0 0 0 0 0 0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by;
Roman Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
CITY_21MC100_002842211