104 East 25th Street New York, New York 10010 www.atc-enviro.com 212.353.8280 Fax 212.353.8306 ASSOCIATES INC.

January 9, 2002

Mr. Bernard P. Orlan Director, Environmental Health & Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101-4008

Re: Air Samples for Polychlorinated Biphenyls & Cyanide P.S.89M ATC Project No. 15-19125-0297

Dear Mr. Orlan;

ATC Associates Inc. (ATC) is pleased to provide this report of the results of air samples for polychlorinated biphenyls (PCBs) and cyanide collected on December 15,2001, at the referenced location. The New York City Board of Education (BOE) requested these samples to evaluate possible contamination in the school building according to the recommendation of T. Fusillo of Environ Corp., consultant to the parents association..

SCOPE OF WORK

Tenzin Namgyal and Wagdi Abdelshahid, Industrial Hygienists of ATC’s New York City office, collected the samples.

The PCB samples were collected using glass fiber filters and Florisil® tubes connected in series to battery-powered sampling pumps set at a flow rate of 0.2 liters per minute (1pm). The sampling time was ten (10) hours. The samples were analyzed by PSC Analytical Services, Inc. (PSC), an American Industrial Hygiene Association-accredited laboratory in Reading, PA. Analysis was performed according to NIOSH Method 5503 (gas chromatography/electron capture detector).

The cyanide sample was collected using a soda lime tube and a battery-powered pump at a flow rate of 0.21pm. Analysis was performed by PSC according to NIOSH Method 6010.

A copy of the laboratory report, giving both sets of results, is provided in the Attachment.

The sampling was performed consistent with generally accepted industrial hygiene, practices. There were inherent limitations created by constraints of time, operational and work practice variability, variations in contaminant concentrations, and sampling and analytical accuracy. The results of the sampling represent conditions found on the dates the samples were collected.

CITY_21MC100_003030712

NYC-WTC_000198894

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000198894Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →