PCM fiber results lab report, Aug 1997

Machine-extracted title · confidence 95%

Laboratory report documenting PCM fiber analysis results for air samples collected on August 27, 1997.

NYC-WTC_000186281
Page image
Scanned page image, NYC-WTC_000186281
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

< ( (

Ciient Maine. ipplied Technology Services, Inc. Phase Contrast Microscopy (PCM) Fiber Results A97195; FH 2nd Floor Lab Flow . Air Fiber Fibers Client Date pie # Sample # / Location Collected Rate Filtered Fields Fibers Density Cone. TWA (liters./!n!n.) (liters) (Fibers/nun ) (FibersZee) 25082797-01 8/27/97 0 0 0 100 0.5 0.64 Blank Footno/es: / 25082797-02 8/27/97 0 0 0 100 0.5 0.64 Blank Footnotes: / 25082797 03 5 390 1950 NA Study Hall in Tent# I. IWA Footnotes: 2 25082797 04 8/27/97 5 390 1950 NA By Handicap Bathroom, OWA Footnotes: 2 25082797-05 5 390 1950 NA Nonh Side in Tent #2. IWA Footnntes: 2 25082797 06 SI27/91 5 390 1950 NA Study Hall, OWA Footnotes: 2 25082797-07 8/27/97 5 390 1950 100 20 25.48 0.005 Al Remote Dccoti, OWA porting Notes: :) Fibers/oc cannot be calculated for samples (or blanks) with no air volume. . '.) Analyst was unable Io quantify Ober concenhilion becalise of overloading of particulate material on the Oller. Analyzed by: Fred Corirossi_____ = Date Analyzed: 8/27/97 ELAP # 11480. Samples analyzed by NlOSll VdOOfAiMBTHOD, Issue #2. 8/15/94: Limit of Detection = 5.5 libers per 100 Fields or 7 Fibers / mm2; This report relates ONLY to the sample analysis exptessei as fibers/sq mm of filler area; ND = no fibers observed; NA = Not Analyzed; Walton - Beckett gratiicule field area 0.00785 mm2; Duration in minutes; TWA = 8Hi TWA calculation assumes zero exposure for remainder of 8 hour period not sampled; Upper 95% Confidence IJinit (Employer's Compliance Test) - Calculated as a one sided UCL to determine 95% certainty of compliance wilfi the 0.01 fiber/oc standard; Estimated relative standard deviation; Iniralab Sr = 0.270, Inter lab Sr = 0.450. Phase Conlrasl Microscope; Olympus, Model Cll-2.

o

S o o o 1 o

Ui o co

NYC-WTC_000186281

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000186281Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →