Proposal for environmental services at 100 Church Street, Nov 2002

Machine-extracted title · confidence 90%

Engineering proposal submitted by TRC Engineers to provide environmental and engineering services at specified locations in November 2002.

NYC-WTC_000182345–000182347
Page image
Scanned page image, NYC-WTC_000182346
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Ms. fielcne Fromm November C 2002 2

PROPOSED SCOPE OF SERVICES

TRC will provide the professionals, equipment and materials required to perform sampling of Mayors Office of Operations representative computer equipment at the 100 Church Street and 40 Worth Street offices. Representative sampling will include sampling of ten percent (10%) of the computer equipment that was impacted by the World Trade Center (WTC) collapse. The seo-ices to be provided will be under the direction of an American Beard of Industrial Hygiene (ABIH) Certified Industrial Hygienist (CIH). Upon receipt of authorization. TRC will perform the following services

Task 1 - Equipment Sampling

TRC will collect and analyze asbestos micro-vacuum samples from within representative impacted computer equipment. A list of computer equipment that was present at 100 Church Street at tlie time of the WTC collapse has been provided to TRC. This equipment is currently located at 100 Church and 40 Wortli Streets. TRC has identified one hundred tliirty six (136) items that liavc vents/fans that could have allowed internal components to be impacted by WTC dust. Sampling of internal components will follow American Society for Testing and Materials (ASTM) Test Method D5755-95 Micro-vacuum Sampling and Indirect Analysis (Filter Sample Analysis) of Dust by Transmission Electron Microscopy (TEM) for Asbesto.s Structure Number Concentration. It is anticipated that up to seventeen (17) samples, including blanks will be collected

All samples will be analyzed by an independent laboratory that is certified by the American Industrial Hygiene Association (AIHA) and the New York State Department of Health (NYSDOH) under the Environmental Laboratory Accreditation Program (ELAP)

Task 2 - Report

Following the completion of tlic site activities, TRC evil] provide and deliver tltree (3) copies of the written Final Report of our findings. The report will i.nckide die following:

• Background Information - detailing facility information, TRC Representative's name(s). certifications, dates of inspections, inspection methodologies, sampling and analysis procedtu'es, etc.,

• Survey arid Sampling Results Summary - identifying results of the visual inspection, identification of areas, results of sampling, and comparison of results to applicable standards, regulations, guidelines and/or background concentrations;

• Analysis of Data and Interpretation of Results, Conclusions and Recommendations;

Report .Appendices - includes report documentation, such as analytical results and chain cf custody forms

FEE TRC will perform the above-defined services for a lump sum fee of S5,930. This fee includes all labor; equipment end materials to complete the above-defined services.

NOIlbyadO dO 33IddO aOAUd 0e;9T 2002-20-330 60/£0’d sz.gx SST 212 t CITY_21MC100_000104292 NYC-WTC_000182346

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000182346Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000177317

Report confirming air monitoring results for asbestos and lead were below detection limits at 100 Church Street.