NYC 9/11 Public Portal Document
1
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
'1
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
I New York, NY 10010 Report Date: 10/23/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
I' With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: 40 Rector Street, 40 Rector St., NY, NY TEM Sample No.; 5741 - 62036
Floorslj-12j3J il5j JJ.
Date Received; 10/23/01 Grid Openings Analyzed:__ 4
/
Project Sample No.: 79-2 Average Grid Opening: 106.00 uin
I Air Volume; 1800 liters Total Area Analyzed: 0.0450 mm2
1J Filter Type: MCE 25 mm diam., Pore Size: 0.45 uro Analytical Sensitivity:22..i2 s/n«n2
Effective Area.- 385 nim2 0.0048 s/cc
ir FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total. struct. Fi1 ter Air
Fibers Bundles Clusters Struct. Struct >=5um Struct/ Struct/oc ngm/m3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
a
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0,0000 0
j
Total asbestos {includes ambiguous structures) 0 0 0.0 0,0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by;
■i.l
Roman Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy