PCM fiber results, 100 Church Street, Feb 2002

Machine-extracted title · confidence 90%

Laboratory report presenting PCM fiber analysis data for ambient air samples collected at 100 Church Street on February 21, 2002.

NYC-WTC_000174386
Page image
Scanned page image, NYC-WTC_000174386
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Sci^Prob#: 202023224 Client Name: TRC Environmental Corporation Phase Contrast Microscopy (PCM) Fiber Results 35052-0000-00007; New York City Law Department; 100 Church Street, AMBIENT Flow Ail- Fiber Fibers SciLab Client Rate Duration Filtered Density Cone. Fields Fibers TWA Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)

01 GS-21202-ASB-0677 2/21/02 5 360 1800 100 2 2.55 < 0.001 6th Floor-Northeast Side Of Hallway 02 GS-21202-ASB-0678 2/21/02 5 360 1800 100 1 1.27 <0.001 6th Floor-Northwest Side Of Hallway 03 GS-21202-ASB-0679 2/21/02 5 180 900 100 1 1.27 < 0.003 Room 6-3 lOA 04 GS-21202-ASB-0680 2/21/02 5 180 900 100 2 2.55 < 0.003 Room 6-316 05 GS-21202-ASB-0681 2/21/02 0 0 0 100 0.5 0.64 Blank Footnotes: 1 06 GS-21202-ASB-0682 2/21/02 0 0 0 100 0.5 0.64 Blank Footnotes: / Reporting Notes: (1) Fibers/cc cannot for Jai^les for blanks) with no air volume. Analyzed by: Marvin Brothers » 1 Analyzed: 2/22/02 Samples analyzed by NIOSH 7400(A) Method, Issue #2, 8/15/94: Limit of Detection= 5.5 fibers per 100 fields or 7 fibers/nim2: This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area: ND=No fibers observed: NA= Not Analyzed; Walton-Beckett graticle field area = 0.00785 mm2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled: Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to determine 95% certainty of compliance widi tlie 0.01 fiber/cc standard: Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45. New York samples (NYSDOH ELAP Lab # 11480): National Institute of Standards and Technology Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the laboratory. AIHA # 102843.

NYC-\/VTC_000174386

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000174386Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →