NYC-WTC_000172164
Document excerpt listing specifications for a Type FR rated, UL Listed fire door or hatch component.
Same agency, volume and box · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗Memorandum responding to Port Authority inspector requests for self-closing access hatch and Inergen system tie-ins for the fuel oil tank room.
NYC-WTC_000172166–000172167Folder label: “SHCA Project No. 5576A®P.A. Inspectors request for Fuel Tank Room.”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
CONNELL ARCHITECTS NO, 3497 J/31
I i I Type"FR" 2-Hour Fire Rated, UL Listed :I wrrawALxrcH I
I RELEWSEHAr^^ ii ? i 3 HourFra Romtf Floor Deer
n«ncao«cDAtMc. r*|2S«M“*»**»__ i :! .1 MRVRaacuMoa^ \ y ^31 ecMMttrteR aPRr* U^IMOBeCMMbM *1 \ /\ I ifly VKMUsa^tBt. ci»Mna«H<u«U \ y \ \\ i \ Ar _J!r / 'cwvMxwfMm 1 I .. tr ^LO^»mi«qAan [ ; .f j- fin r 4 V* ookoiere \ T0l«BM*1HRAT«e. I uwniM IMWIB m auQ amBOT onu*
rnui •MICK
Click on the drawing above to download DXF file In .exe fdtmtat I SPECIFIC/ TIONS: Type FR. Fire rated floor access door shall be Type FR- as manufactured by The Bilco Comr any. Door and frame assembly shall be tested in accordance with ASTM E 119 and UL Listed as having a 2- lour fire rating when exposed to fire from the underside. In the closed position, the temperature on the unexpo ;ed surface of the door assembly shall not exceed 325 degrees F (162 degrees C) above ambient for the duri tion of the 2-hour period. Manufacturer shall submit a test report certifying this performance. -1 I
J Door leaf s tall have a 1" (25.4mm) fillable pan to receive concrete and (specify flooring'material type and w sight). Door leaf shall be constructed of 1/4" (6.35mm) aluminum and built to withstand a live load of 150 psf (73 2 kg per sq. meter). Frame shall be 1/4" (6.35mm) extruded aluminum with neoprene cushion and 'I continuous anchor flange. i
Door shall I le equipped with a self-contained, pneumatic, automatic closing system which will close land latch the door le< f in the event of fire. A hydraulic hold-open system shall automatically hold the door in the open I position. 1 I Compressi »n spring operators enclosed in telescopic tubes Shall be provided for smooth, easy operation I throughout the entire arc of opening and closing. Continuous hinge shall be heavy duty Type 316 stainless steel. A Tyi« 316 stainless steel slam latch with gasketed cover plug and removable turn handle (tcipsidej and cable relea ie handle (underside) shall be provided. Factory finish shall be mill finish aluminum with bituminous coating apt lied to the exterior of the frame. 1 ;i .1 Door asser ibly shall be installed in a UL Listed fire rated floor/ceiling assembly in strict accordance with manufactui sr's instructions and details. Manufacturer shall guarantee against defects in material arid i! workmanst ip for a period of five (S) years.
I I -Return to Home Page | Commercial Products | Local Sales Reps | Literature Request i
,1 t"® 9“^ 1
6-7 J http.Z/wwbTpilc ,.. ,bilcc<com/com/pagc27.htm] i/q/nn NYC-WTC_000172167
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000172164
Document excerpt listing specifications for a Type FR rated, UL Listed fire door or hatch component.
Same agency, volume and box · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000172163
Memorandum responding to Port Authority inspector requests for self-closing access hatch and Inergen system tie-ins for the fuel oil tank room.
2 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000173768
Document listing requests for clarifications on ductwork and column modifications with associated response dates.
Same agency, volume and box · similarity 0.923
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000173761
Log sheet tracking construction inquiries regarding duct offsets and field conditions with pricing responses.
Same agency, volume and box · similarity 0.922
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000173374
Architectural specification sheet detailing door models, dimensions, fire ratings, and security features for the OEM facility.
1 shared non-person entities · Same agency, volume and box · similarity 0.921
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000171743
Facsimile cover sheet from Ambassador Construction Co. Inc. dated June 11, 1999 regarding work at 7 World Trade Center.
Same agency, volume and box · similarity 0.920
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000173753
Record of construction inquiries concerning duct offsets and wet column encroachments with issued responses.
1 shared topics · Same agency, volume and box · similarity 0.919
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000168439
Change order for $85,893 covering support structures, concrete encasement, routing, and patching for fuel oil lines and enclosures at 7 World Trade Center.
3 shared non-person entities · Same agency, volume and box · similarity 0.918
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000173529
Letter from law firm to City regarding administrative matter related to 7 World Trade Center.
2 shared non-person entities · Same agency, volume and box · similarity 0.917
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000171318
Contractor submission of revised change order #44R for fuel oil line supports, enclosures, and new routing at 7 World Trade Center.
3 shared non-person entities · Same agency, volume and box · similarity 0.915
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000171829
Proposal for change order #2 to install cabinets, countertops, and paneling at the Office of Emergency Management.
1 shared topics · Same agency, volume and box · similarity 0.913
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000169205
Document summarizing fire service activities or inspections performed at the specified location.
Similar document embedding; no shared entity or topic indexed. · similarity 0.914
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000172164
Document excerpt listing specifications for a Type FR rated, UL Listed fire door or hatch component.
Similar indexed content
NYC-WTC_000172163
Memorandum responding to Port Authority inspector requests for self-closing access hatch and Inergen system tie-ins for the fuel oil tank room.
Similar indexed content
NYC-WTC_000173768
Document listing requests for clarifications on ductwork and column modifications with associated response dates.
Similar indexed content
NYC-WTC_000173761
Log sheet tracking construction inquiries regarding duct offsets and field conditions with pricing responses.
Similar indexed content
NYC-WTC_000173374
Architectural specification sheet detailing door models, dimensions, fire ratings, and security features for the OEM facility.
Similar indexed content