Project No.5576A Total RFI's Received 12
04
(S Revised 07/22/98 Total Responses Received 10
RFILOG
0.
RH OAIE fStBJECWmSnMIDWG Ha RSPONSE UTE «BU$DAYS|nMiMl«a
NO. RKTD RESP.
1 7/17/98 RETURN AIR DUCT ASOBE THE TYPE » 3 WALL BETWEEN FSK-1 WAS ISSUED ON 7/22/90 FOR PRICING OF OFFSET 7/22S8 4 FIELD CONDiTfON.
EOC ANO CORR. INTERFERESC WITH FULLHT. fSLAB TO 3PLY WALL. AMBASSADOR TO PRICE MOVING AND/ OR
SLAB) PARTITION. PRVIDING NEW DUCT TO CLEAR WALL.
2 7/17/9S IN CORR. ADJACENT TO ROOM 2343 THERE ARE (2) WET COLUMNS WILL BE FURRED OUT AS PER REViSED 7/22^8' 2
Ct COLUMNS WITH RISER PIPING ENCROCHING DRAWINGS, ISSUED FOR BULLETIN » 1 DATED 07/24«8 (
I- APPROXIMATELY 13* INTO OORR. VERBAL FIELD INSTRUCTIONS WHERE ISSUED 07/21/98)
3 7/17/98 IF DOOR 7A IS TO BE BLAST PROOF. THE MANUFACTURER" THE DOOR IS HM, BUT THE SPECS CALL FOR LAMINATION 7/21/98 2
Ct ADVICES THAT THEY CAN NOT PROVIDE WITH EMI OF VENEER THE SHIELDING COULD BE LAMINATED TO THE
o
Q SHIELDING. DOOR AND THEN COVERED WITH THE VENEER.
S
am 4 7/17798 HURRICANE WALL COhORACTOR WOULD LIKE SHCA TO SHCA WILL ACCEPT PAhEL SYSTEM AS LONG AS 7/21/98 2 CANTOR HAS
CONSIDER ALT. PREFAB PANEL SYSTEM. ACCEPTED
5 CONTRACTOR PROVIDES SHOP DRAWINGS AND
STRUCTURAL CALCULATIONS THAT PROVE IS EQUAL TO DRETAtLS FOR
DESIGN. STEEL PLATE
5 7/17/98 DOES CONC. CURB AT 7TH, FLOOR AND 23Rb. FLOOR HAVE= liS^P^CdNVER^IONWnH STRUCTURAL EN^NKO 7/20/98 3
TO BE CHOPPED INTO THE SLAB. CAN WE ACCOMPLISH THE IS NOT ACCEPTABLE TO SHOOT RODS OR ANCHORS TO
SANE THING BY DRIVING OR SHOOTING IN ANCHORS SLAB
6 7/31/98 DUCT INTEFERENCE WITH WALL BETWEEN CORRIDOR AND BUILD (2) LAYER WALL TO UNDERSIDE OF DUCT AND ADD 8/4/98 4
LIBRARY SOUND INSULATION ABOVE CEILING TILES A MINIMUM OF
2'-0- FROM WALL ON BOTH SIDES OF CORRIDOR,
CM
iJD
7 7/31/98 DUCT INTEFERENCE WITH WAU BETWEEN CORRIDOR AND BUILD (2) LAYER WALL TO UNDERSIDE OF DUCT AND ADD 8/4/98 4
cn ’ TRAINING ROOM. SOUND INSULATION ABOVE CEILING TILES A MINIMUM OF
Tj-
cn 2'-0" FROM WALL ON BOTH SIDES OF CORRIDOR.
CM
8 7/31/98' HEIGHT OF OUTLET SHOWN ON DWG A-23-3 AND A-234 LOCATE OUTLETS AS PER DRAWING A-23-4 18" A.F F B/4/98 4
DIFFER
cn
rd
o 9 '7/31/98 ■ OVERLY REQUESTED INFORMATION ON UL LABELS. ( DO NO THIS ARE NOT RATED DOORS. 8/4^8"
LBR DOORS HAVE TO HAVE UL LAVELS.)