OEM Swanke Hayden Connell Architects 7 World Trade Center Project No.5576A Total RFI's Received 12 04 (S Revised 07/22/98 Total Responses Received 10

RFILOG 0. RH OAIE fStBJECWmSnMIDWG Ha RSPONSE UTE «BU$DAYS|nMiMl«a NO. RKTD RESP.

1 7/17/98 RETURN AIR DUCT ASOBE THE TYPE » 3 WALL BETWEEN FSK-1 WAS ISSUED ON 7/22/90 FOR PRICING OF OFFSET 7/22S8 4 FIELD CONDiTfON. EOC ANO CORR. INTERFERESC WITH FULLHT. fSLAB TO 3PLY WALL. AMBASSADOR TO PRICE MOVING AND/ OR SLAB) PARTITION. PRVIDING NEW DUCT TO CLEAR WALL.

2 7/17/9S IN CORR. ADJACENT TO ROOM 2343 THERE ARE (2) WET COLUMNS WILL BE FURRED OUT AS PER REViSED 7/22^8' 2 Ct COLUMNS WITH RISER PIPING ENCROCHING DRAWINGS, ISSUED FOR BULLETIN » 1 DATED 07/24«8 ( I- APPROXIMATELY 13* INTO OORR. VERBAL FIELD INSTRUCTIONS WHERE ISSUED 07/21/98)

3 7/17/98 IF DOOR 7A IS TO BE BLAST PROOF. THE MANUFACTURER" THE DOOR IS HM, BUT THE SPECS CALL FOR LAMINATION 7/21/98 2 Ct ADVICES THAT THEY CAN NOT PROVIDE WITH EMI OF VENEER THE SHIELDING COULD BE LAMINATED TO THE o Q SHIELDING. DOOR AND THEN COVERED WITH THE VENEER. S am 4 7/17798 HURRICANE WALL COhORACTOR WOULD LIKE SHCA TO SHCA WILL ACCEPT PAhEL SYSTEM AS LONG AS 7/21/98 2 CANTOR HAS CONSIDER ALT. PREFAB PANEL SYSTEM. ACCEPTED 5 CONTRACTOR PROVIDES SHOP DRAWINGS AND STRUCTURAL CALCULATIONS THAT PROVE IS EQUAL TO DRETAtLS FOR DESIGN. STEEL PLATE 5 7/17/98 DOES CONC. CURB AT 7TH, FLOOR AND 23Rb. FLOOR HAVE= liS^P^CdNVER^IONWnH STRUCTURAL EN^NKO 7/20/98 3 TO BE CHOPPED INTO THE SLAB. CAN WE ACCOMPLISH THE IS NOT ACCEPTABLE TO SHOOT RODS OR ANCHORS TO SANE THING BY DRIVING OR SHOOTING IN ANCHORS SLAB

6 7/31/98 DUCT INTEFERENCE WITH WALL BETWEEN CORRIDOR AND BUILD (2) LAYER WALL TO UNDERSIDE OF DUCT AND ADD 8/4/98 4 LIBRARY SOUND INSULATION ABOVE CEILING TILES A MINIMUM OF 2'-0- FROM WALL ON BOTH SIDES OF CORRIDOR, CM iJD 7 7/31/98 DUCT INTEFERENCE WITH WAU BETWEEN CORRIDOR AND BUILD (2) LAYER WALL TO UNDERSIDE OF DUCT AND ADD 8/4/98 4 cn ’ TRAINING ROOM. SOUND INSULATION ABOVE CEILING TILES A MINIMUM OF Tj- cn 2'-0" FROM WALL ON BOTH SIDES OF CORRIDOR. CM 8 7/31/98' HEIGHT OF OUTLET SHOWN ON DWG A-23-3 AND A-234 LOCATE OUTLETS AS PER DRAWING A-23-4 18" A.F F B/4/98 4 DIFFER cn

rd o 9 '7/31/98 ■ OVERLY REQUESTED INFORMATION ON UL LABELS. ( DO NO THIS ARE NOT RATED DOORS. 8/4^8" LBR DOORS HAVE TO HAVE UL LAVELS.) ID cn ij*

o

IS.1

NYC-WTC_000173768

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000173768Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

RFI Log for 7 World Trade Center, July 1998 · Box 7DCAS

NYC-WTC_000173795

Request for Information log documenting RFIs regarding HVAC duct offsets and wet columns at the Mayor's Office of Emergency Management site.

1 shared non-person entities · Same agency, volume and box · similarity 0.976

machine-extracted · confidence unavailable · Check page ↗
RFI Log, 7 World Trade Center, July 1998 · Box 7DCAS

NYC-WTC_000173770

Request for Information log for 7 World Trade Center project tracking 24 RFIs with responses regarding return air duct and corridor construction design.

1 shared non-person entities · Same agency, volume and box · similarity 0.966

machine-extracted · confidence unavailable · Check page ↗
RFI log entries, Sep 1998 · Box 7DCAS

NYC-WTC_000166759

Log entries recording specific requests for information regarding air ducts and wet columns at 7 World Trade Center in September 1998.

1 shared non-person entities · Same agency, volume and box · similarity 0.965

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

RFI log entries, Sep 1998 · Box 7DCAS

NYC-WTC_000166759

Log entries recording specific requests for information regarding air ducts and wet columns at 7 World Trade Center in September 1998.

Filed in the same folder

Compare copies and versions →