w4/zy/yu A)-01 tybib 231 /luu I-UN I ANA ME I AL 0008/013
2 - OVERLY BLAST DOORS - SHORT FORM SPECIFICATION GUIDE
B. Design Criteria: Pre-engincered swinging doors to be Overly Model VERB or equal. The door, frame and restraining haidwaic shall be designed to withstand psf sealing the door into the frame and___ psf unseating the door from the frame (rebound) The door system shall be fully operable afier application of the specified blast.
The char! below shows the stanJarJ shes fur the Overly Model ITLliH single door. Also shown l.f the rnaximuni safe working load each model can withstand for both the .seating and unseating directions. Your design blast pressure must fall within the capacitie.s listed for the applicable opening size. If your blast pressure exceeds the capacitie.s listed below, consider the Overly Model LRB (Tmw Range Blast) door system. Contact Overly for more information on this product line.
Model Door Max. Max. UL Door Lock Qty. Leaf No. Opn'g Seating Unseating Labels Thick Type Hinges Weight Size Pressure Pressure (lb)
36 X 84 396 psf 174 psf 3 184 36x96 347 p.’jf 153 psf 3 hr, ANSI 4 222 VLRB 42 x 90 325 psf 121 psf ’’A” 1 3/4" J56.13 4 273 48x84 297 psf 114 psf Max. 3 288 48 X 96 260 psf 100 psf 4 293
C. Product Description: Doors shall be a nominal 1-3/4" thick, full flush, constructed and reinforced to resist the blast forces specified. Design door hardware and reinforcements to transfer all applicable blast loadings to frame. Design frame anchors to transfer all blast loadings to walls or structural sub-frame embeds. Frames shall be [CAoo5e one: Hollow metal formed steel with formed stops /or / structural steel channel with welded slops], three sided, factory reinforced and tapped for hardware. Frame anchorage shall be [CAorxre one: CMU strap anchors / concrete expansion anchors / poured-in-place / weld-in configuration for steel walls].
Fire rating; Those openings scheduled as fire rated shall liave been tested by and bear the labels of Underwriters Laboratories marked for 3 hour, A label for flush doors and 1-1/2 hour, B label for doors with a vision lite. (Maximum vision area: 100 square inches).
The lockset shall conform to ANSI Standard A156.13. Functions as specified. The lockset shall be suitable for use with project mastcfkcycd key cylinders were specified.
r NYC-WTC_000166816
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000166793
Engineering calculation sheet for beam column design addressing lateral torsional buckling at World Trade Center.
Same agency, volume and box · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000167926
Fax document detailing ballistic aluminum door specifications and construction requirements for a facility.
1 shared topics · Same agency, volume and box · similarity 0.921
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000173050
Fax cover sheet from Steelcraft transmitting documents regarding folding gates and fire doors.
1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.920
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000172296
Fax cover sheet from Steelcraft transmitting documents regarding folding gates and grilles for the World Trade Center project.
1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.917
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000173374
Architectural specification sheet detailing door models, dimensions, fire ratings, and security features for the OEM facility.
1 shared topics · Same agency, volume and box · similarity 0.907
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000172431
Product feature description for Insulgard ICDS bullet-resisting door systems including heavy-duty aluminum construction dated May 1998.
1 shared topics · Same agency, volume and box · similarity 0.906
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000172426
Fax quote form from Insulgard Corporation for bullet-resisting door systems at the World Trade Center dated May 1998.
1 shared topics · Same agency, volume and box · similarity 0.903
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000173223
Supplement to HVAC specifications detailing discharge plenum construction standards for emergency generators at the Mayor's Office of Emergency Management.
1 shared topics · Same agency, volume and box · similarity 0.902
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000168106
Portfolio document detailing selected boardroom and conference room projects completed by KBI Systems over three years.
1 shared topics · Same agency, volume and box · similarity 0.901
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000173529
Letter from law firm to City regarding administrative matter related to 7 World Trade Center.
Same agency, volume and box · similarity 0.900
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000166488
Department of Buildings report containing findings and recommendations regarding the World Trade Center site.
Similar document embedding; no shared entity or topic indexed. · similarity 0.919
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000165271
Engineering drawings and specifications for replacing a high-pressure water line under the Lincoln Tunnel contract.
Similar document embedding; no shared entity or topic indexed. · similarity 0.901
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000172431
Product feature description for Insulgard ICDS bullet-resisting door systems including heavy-duty aluminum construction dated May 1998.
Similarity score 0.927 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000167926
Fax document detailing ballistic aluminum door specifications and construction requirements for a facility.
Similarity score 0.922 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000172296
Fax cover sheet from Steelcraft transmitting documents regarding folding gates and grilles for the World Trade Center project.
Similarity score 0.920 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000167925
Technical documentation regarding ballistics protection equipment and laminate materials for 7 WTC facility installation.
Similarity score 0.918 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000172164
Document excerpt listing specifications for a Type FR rated, UL Listed fire door or hatch component.
Similarity score 0.916 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000166793
Engineering calculation sheet for beam column design addressing lateral torsional buckling at World Trade Center.
Similarity score 0.914 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000166793
Engineering calculation sheet for beam column design addressing lateral torsional buckling at World Trade Center.
Similar indexed content
NYC-WTC_000167926
Fax document detailing ballistic aluminum door specifications and construction requirements for a facility.
Similar indexed content
NYC-WTC_000173050
Fax cover sheet from Steelcraft transmitting documents regarding folding gates and fire doors.
Similar indexed content
NYC-WTC_000166488
Department of Buildings report containing findings and recommendations regarding the World Trade Center site.
Similar indexed content
NYC-WTC_000172296
Fax cover sheet from Steelcraft transmitting documents regarding folding gates and grilles for the World Trade Center project.
Similar indexed content