1. All alteration work shall be done in a careful and professional manner. hie unnecessary damage shall be allowed to the "pedestrian" piers below Elev. +5 or to the relieving conposite deck. The Subcontractor shall be solely responsible for the removal, handling, transportation and disposal of all materials of all kinds demolished under the terms of this Section cf the Specifications, and for all arrangements, permits, costs or charges incident thereto. 2. Concrete shall be chipped or sawed to a rough horizontal plane at Elev. +5 and tlie rebars burned off flush with the surface of the concrete at the limits shown on tlie Drawings. 3. The 550 psf loading limit for existing relieving platforms will not allow the placement on the platform of heavy equipment such as . Dynahoe or ccirpressor unless timbers distribute the loadings satisfactorily. Prior approval of the Foundation Engineer is required for ally procedure in^/olving placement of heavy equipment on the platform.

BPC-CQMMERCIAL CENTER- 02200-2 ALTERATION

NYC-WTC_000165142

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000165142Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000165064 · Box DEP Box 44

Request documentation regarding the relocation of river water intake lines and pump station utilities at the World Trade Center.

Filed in the same folder

Compare copies and versions →