debris. Post cleaning air sampling shall be performed upon successM^ visual inspeetfon and
completed.- within 24 hours. A success&l visual inspection shaU be an mspeeti.on that verifies
the absence of dust and debris. ; ■
b. All surfaces must be completely dry prior to (he start of sampling. ■
c. Window air eonditiotting units where-applicable shall benai/operated at least I S minutes
prior to the start ofsampling. Th^ units shall operate continuously' throughout
the sampling.
d. Based on consultation with-resident,-aggressive or modified aggressive air sampling wi 11 be
conducted upon completion ofcleaning. In aggressive air monitoring sampling situations,
before the start of sampling, a 1 horsepower electric leaf blower will be used to direct
exhaust air against walls, ceilings, floors and other surfaces. When directing the exhaust.
caution shall be taken to minimize disturbance and potential damage to furnishings and
personal belongings. The procedure descri bed below for modified aggressix'e sampling
techniques will also be employed
e. In modi tied aggressive sampling, one 2()-indi fan shall be installed per 10,000 cubic feet of
room space and run al low speed. The Ian shall operate continuously throughout sampling
and shall not be turned off until sampling is completed.
£ For studio apartments 3 samples sha!! be col leeted. For 1 -bedroom apartments and above
5 samplesshall be collected. Sampling equipment shalI be placed in 1 iving areas and away
from obstructions. The sampling cassette must be placed on a tripod and not taped to
existing surfaces, V ■■ c
g- Common spaces will be sampled without the use of forced air devices (fans, leaf blowers
etc). For small spaces. Ic.ss than 160 square feel. 3 .samples will be collected. For large
spaces greater than 160 square foel and less than 25,000 square feet S samptes will be
collected. For spaces greater than 25,000 square feet, 1 sample will be collected for each
5,000 square feet. Sampling equipment shall be placed away from obstructions. The
sampling cassette must be placed on a tripoddirected downward at a 45 degree angle and
not taped to existing surfaces.
h. Air samples shall be collected in accordance with the procedures specified in NIOSIl 7400
Method for PCM and 7402 for TEM. Air sampling cassettes need to be monitored to
ensure pumps are not clogging by monitoring flowrates, friemiramum sampling volume
required is 36(fo liters. . ■
Ihe contractor shall document all the necessary mfonnationregarding saoipling activities, fill
out all field logs, data sheets, and chain-of-custody forms. Ilie contractor shall use F'2L for
dl sample and chain-of-cuslody documentation. Saraplesmust belabdediandaccompaniM
with completed chain ofcustodyfonnsbeforeshippingtofliedesignated laborafoty.Tlie
label must include the EPA Project Tracking Number. Satepies will be packed, sealed and
tor analysis to EMSL laboratories at: 307 W. 38* St., New York, New York 212-290-
0051. , , ■ 3
j- All information must be maintained using the secure EPA website(url, user name and
password to beprovided by EPA). Oates for momtoriflg and/or cleaning shallbe provided
to EPA aaci DEP electronically in an EPA approved format withia 24hours. Infennation on
sampling activities (date, sample ID) will be provided to EPA, via &e website, within 24