a. Sampling shall not begin until a visual inspection confirms the absence of visible dust
and debris. Post cleaning air sampling shall be performed upon successful visual
inspection and completed within 24 hours. A successful visual inspection shall be an
inspection that verifies the absence of dust and debris.
b. All surfaces must be completely dry prior to the start of sampling.
c. Window air conditioning units where applicable shall be run/operated at least 15
minutes prior to the start of sampling. The air conditioning uniLs shall operate
continuously throughout the sampling.
d. Based on consultation with resident, aggressix e or modi issive air sampling
will be conducted upon completion of cleanin”. In ;iggres; mitoring samjiling
situations, before the start of sampling, a 1 horsepower electric hcaf blower will he
used to direct exhaust air against walls, j ceilings, floor^aiul olhi cr surfaces. When
directing the exhaust, caution shall be tai cn to minimize disturb: Biential
damage to furnishings and personal beloq s. The procedure desi ■clow for
modified aggressive sampling techniques a 11 so be employed
e. In modified aggressive sampling, one 20-inch fair installed per 10,000 cubic
feet of room space and run at low speed. The fan sH te continuously throughout
sampling and shall not be turned off until sar ipling is c
f. For studio apartments 3 samples shall be co 1 -bedroom apartments and
above 5 samples shall be collected. Sampling * uuipinent all be placed in living areas
and away from obslructions. The sampling cal € placed on a tripod and not
taped to existing surfaces.
g- Common spaces will be sampled without tl le use of forced air devices (fans, leaf
blowers etc). For small spaces, less than 160 iquare feet, 3 samples will be collected.
For large spaces greater than 160 square id less than 25,000 square feet 5 samples
4will be coll© . I or space .'r th;in 25,000 square feet, 1 sample will be
colkvled fore 5,()(i() squall Sampling equipment shall be placed away from
obswuctions.- ing cassette must be placed on a tripod directed downward at
o as angle .nu ot raped to existing surfaces.
h. des shall be t lecicd in accordance with the procedures specified in NIOSH
cthod lor P; ^Bnd 7402 for TEM. Air sampling cassettes need to be
TOoniiored 1 ensure; pumps are not clogging by monitoring flow rates, the minimum
■<
sampling xl ume required is 3600 liters.
i The contr^ or shall document all the necessary information regarding sampling
activities, fl out all field logs, data sheets, and chain-of-custody forms. The contractor
A shall use F2I.. for all sample and chain-of-custody documentation. Samples must be
labele^^H accompanied with completed chain of custody forms before shipping to the
designated laboratory. The label must include the EPA Project Tracking Number.
Ah Samples will be packed, sealed and for analysis to EMSL laboratories at: 307 W. 38*
'St., New York, New York 212-290-0051.
J- All information must be maintained using the secure EPA website(url, user name and
password to be provided by EPA). Dates for monitoring and/or cleaning shall be
provided to EPA and DEP electronically in an EPA approved format within 24 hours.
Information on sampling activities (date, sample ID) will be provided to EPA, via the
website, within 24 hours of completion of evaluation.