a. Sampling shall not begin until a visual inspection confirms the absence of visible dust
and debris. Post cleaning air sampling shall be performed upon successful visual
inspection and completed within 24 hours. A successful visual inspection shall be an
inspection that verifies the absence of dust and debris.
b. All surfaces must be completely dry prior to the start of sampling.
c. Window air conditioning units where applicable shall be run/operated at least 15
minutes prior to the start of sampling. The air conditioning units shall operate
continuously throughout the sampling.
d. Upon completion of the cleaning, either aggressive or modified aggressive air
sampling procedures will be conducted to verify attainment of the clean-up
criteria. Aggressive or modified aggressive air sampling will toe mined for Scope A
clean-ups, based on consultation with resident. In aggressive air monitoring
sampling situations, before the start of sampling, a 1 horsepower electric leafblower
will be used to direct exhaust air against walls, ceilings, floors and othersurfaces. When
directing the exhaust, caution shall be taken to minimize disturbance and potential
damage to furnishings and personal belong rigs. The procedure described below for
modified aggressive sampling techniques i [1 also be employed
e. In modified aggressive sampling, one 20-inc [fan shall be Instiled per 10,000 cubic feet
of room space and run at low spi ||:,shall operate continuously throughout
sampling and shall not be turned offuntil! is completed.
f. For studio apartments 3 shall ji Cted. For 1-bedroom apartments and
above 5 samples shall be c^flcted. Sampling qipment shall be placed in living areas
and away from obstructions. The sampling cattle must be placed on a tripod and not
taped to existing surfaces.
g- Common spaces will be sampled withoi|^e use of forced air devices (fans, leaf
jblowers etc). For small spaces, less than 160 square feet, 3 samples will be collected.
For large spaces greater than 160 square feet and less than 25,000 square feet 5 samples
wiSbe collected. For spaces greater than 25,000 square feet, 1 sample will be collected
for each 5,000 square feet. Sampling equipment shall be placed away from
The WB^BWassette
J- -v must be placed
r on a tripod
r directed downward at
a 45 degree angle and^^hp| taped to existing surfaces.
h. Air samples shall be collected in accordance with the procedures specified in NIOSH
7400 Method for Ur PCM and 7402 for TEM. Air sampling cassettes need to be
monitored to ensu ■e pumps are not clogging by monitoring flow rates. The minimum
sampling volume required is 3600 liters.
1. 24-hour turn-around-time shall be specified for the analysis of all post-cleaning air
samples for Scope B cleanups.
j. The contractor shall document all the necessary information regarding sampling
activities, fill out all field logs, data sheets, and chain-of-custody forms. The contractor
shall use F2L for all sample and chain-of-custody documentation. Samples must be
labeled and accompanied with completed chain-of-custody forms before shipping to the
designated laboratory. The label must include the EPA Project Tracking Number.
Samples will be packed, sealed and for analysis to EMSL laboratories at: 307 W. 38*
St., New York, New York 212-290-0051.
k. All information must be maintained using the secure EPA website (url, user name and