NYC 9/11 Public Portal Document

e ♦ Gilsenan, Michael From: [email protected] Sent: Wednesday, March 26, 2003 8:42 AM To: Theodorellys, Penny Cc: Radhakrishnan, Krish; Gilsenan, Michael; [email protected]; [email protected] Subject: Re: FW: Revised PAH results

a I

R03030157 revised R03030158 revised Report, pdf Report pdf Penny,

Thanks for sending the revised PAH results. The detection limit seems to be the appropriate one, however I would need one additional piece of information from the laboratory to accept the results as valid. The additional information would be a letter (on the laboratory's letterhead) explaining the change in detection limits on the analytical reporting sheets with an attachment of one of the lab sheets/chromatographs that shows the detection limit used during the analysis. I am only requesting this because of the discrepancy highlighted below.

Based on the original PAH results that I received, it appears that the PAH samples were analyzed using a detection limit of 5 ug. The analyses were all conducted on March 10 and 11. The analytical results sheets had a date on top of the page of March 14. The revised PAH results that I received yesterday are identical to the previous results with the exception that the detection limit is now reported as 1 ug and the date at the top of the pages is March 24. The revised results have the same analysis dates and times as the previous samples. Based on the revised results, the only interpretation of this can be that the original analysis was in fact conducted with a detection limit of 1 ug, but erroneously reported as 5 ug, which would make reanalyzing the samples unnecessary (scenario 1). However, I was under the impression that the original detection limit used was 5 ug, and that the only way to get revised results at a detection limit of 1 ug would be to re-run the samples using the lower detection limit. This would result in the date and time analyzed to differ between the original and revised analytical data sheets (scenario 2). Thus, I need confirmation regarding which of the two scenarios above occurred.

Thanks,

Chuck Nace Environmental Toxicologist

USEPA - Region 2 290 Broadway - 18th Floor New York, NY 10007-1866

212.637.3459 212.637.4164 212.637.4360 - fax [email protected]

"Theodorellys, Penny" To: Charles Nace/R2/USEPA/US@EPA

1

NYC-WTC_000163082

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000163082Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →