NYC 9/11 Public Portal Document
<1 -*■
Gilsenan, Michael
From: Usbeck, Fred [[email protected]
Sent: Wednesday. March 26. 2003 2:23 PM
To: [email protected]; Theodorellys. Penny
Cc: Radhakrishnan. Krish; Gilsenan. Michael; [email protected] ; Playez. Dave;
Johnston. Mark
Subject; RE: FW; Revised PAH results
Chuck
In response to your question about the change in the reporting limit for the
PAH wipe samples:
Our normal PQL (practical quantitation limit) is 5 ug for each PAH for this
method, however, our MDL (method detection limit) is 1 ug for each PAH. For
this reason we did not need to rerun these samples - we went back to the raw
data to verify that there weren't any "hits" above the 1 ug MDL for these
samples, and reprinted the report with the revised reporting limit.
I will ask the guys in the lab to print a few chromatograms to demonstrate
the new 1 ug DL and send them to Andrew at JLC. I'm sure he won't mind
sharing these with you.
If you have any other questions please get back to me.
thanks! Fred
---- Original Message----
From: [email protected] [mailto:[email protected]]
Sent: Wednesday, March 26, 2003 8:42 AM
To: Theodorellys, Penny
Cc: Radhakrishnan, Krish; Gilsenan, Michael;
[email protected] ; Usbeck, Fred
Subject: Re: FW: Revised PAH results
Penny,
Thanks for sending the revised PAH results. The detection limit seems
to be the appropriate one, however I would need one additional piece of
information from the laboratory to accept the results as valid. The
additional information would be a letter (on the laboratory's
letterhead) explaining the change in detection limits on the analytical
reporting sheets with an attachment of one of the lab
sheets/chromatographs that shows the detection limit used during the
analysis. I am only requesting this because of the discrepancy
highlighted below.
Based on the original PAH results that I received, it appears that the
PAH samples were analyzed using a detection limit of 5 ug. The analyses
were all conducted on March 10 and 11. The analytical results sheets
had a date on top of the page of March 14. The revised PAH results that
I received yesterday are identical to the previous results with the
exception that the detection limit is now reported as 1 ug and the date
at the top of the pages is March 24. The revised results have the same
analysis dates and times as the previous samples. Based on the revised
results, the only interpretation of this can be that the original
analysis was in fact conducted with a detection limit of 1 ug, but
erroneously reported as 5 ug, which would make reanalyzing the samples
unnecessary (scenario 1). However, I was under the impression that the
original detection limit used was 5 ug, and that the only way to get
revised results at a detection limit of 1 ug would be to re-run the
1
NYC-WTC_000163085
OCR can misread numbers and units. Confirm readings against the page image before using them.