NYC 9/11 Public Portal Document
WKP
LABORATORIES, INC
AIR SAMPLE ANALYSIS REPORT I
PHASE CONTRAST MICROSCOPY revised 4/18/02
CLIENT; WARREN & PANZER ENGINEERS, P.C.
TURNAROUND TIMS 3«HR8
WKP FILE# 801-01
SAMPLE DATE 4/18/02
WKPLOSLD.# N02Q41S4, N0294;66, snd N02041S6
RECEIVED OATH 4/18/02
Contreel#! WTCAR2
ANALYSIS DATE 4/18/02
REPORT DATE 4/19/02
CLIENT JOB: NYC Department of Environmental ProteoBon
CLIENT JOB#: 1078.01.01
LOCATION S.W. Area/She Map
analysis: AIRBORNE FIBER COUNTING, PHASE CONTRAST MICROSCOPY. NIOSH 7400. NIOSH PAT Lab NO. 07186: NY
COLLECTION DEVICE: 25 mm MCE Filter Cassette; Ceileelicn Area « 365 eq mm;
SAMPLE WERE COLL5CTEO BY; Benny Oiambnone, J. Garcia, and Festy Oamwegie
SUMMARY OP analysis
CLIENT FIBERS/ FIBERS/
SAMPLE# Site# SAMPLE LOCATION VeL sq mm co
1079.01.01 001 27 Gateway Plaza Park Ama 675 0.00 <0.004
002 31 South End Ave, and Albany Street 873 0.00 <0.004
003 32 West Street and Albany Place 675 0.00 <0.004
004 3aA Rector Place by the Park Place 675 0.00 <0.004
005 34 W. Thames Street • Along Waterfront 67S 0.00 <0.004
006 37 Weet of Third Place 87S 0.00 <0.004
007 6 West Street and Warren Street 67S 0.00 <0.004
008 4 Rivar Terrace end Chambers Street 675 0.00 <0.004
009 8A River Terrace Park Area Between Park Plaoa and Warren Street 675 0.00 <0.004
010 9 River Terrace end Perk Piece Weet 675 0.00 <0.004
011 17 River Terrace and Vesey 675 0.00 <0.004
012 7 Warren Street and North End Avenue 675 0.00 <0.004
013 10 North End Avenue Park place Weet 676 0.00 <0.004
014 28 Trinity Place end Thames Street 673 6.40 0.004
016 21 Fulton and Church Street 675 6.10 <0.094
016 20A Vesey Street and West Broadway 67S 0.00 <0.004
017 16 Park place and Church street 67S 10.20 OJXW
016 12 Murray street and Churoh Street 675 9.60 0.006
019 18 Perk Place and Greenwich Street 875 0.00 <0.004
020 11 Murrey Street and Greenwich Street 676 12.70 0.007
021 Field Blank 0.00
022 Field Blank 0.00
NOTES: 1.5.5 fibera/100 fields was used to ca
2. Samples were not collected by WKP Laboratories. Inc.
3. The Federal EPA Clearance Critical following an asbestos abatement project Is 0-010 fibers/co.
4. PCM air samples win be disposed of after 3 months unless otherwise directed by client in writing.
CMs Pepino
lABORATeWf ANALYST LABORATORY DIRECTOR