NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 42/WTC- Air Data
Document / 3 pages

WKP Air Sample Analysis Report for WTC Sampling, May 2002

Machine-extracted title · confidence 95%

Phase contrast microscopy report for airborne fiber counting at the World Trade Center site dated May 2002.

NYC-WTC_000161810–000161812

Folder label: “WTC- Air Data

Page image
Scanned page image, NYC-WTC_000161812
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

WKP LABORATORIES, INC AIR SAMPLE ANALYSIS REPORT PHASE CONTRAST MICROSCOPY

CLIENT; WARREN & PANZER ENGINEERS, P.C. TURNAROUND TIME 24HRS

WKP FILE# 501-01 Sample date 4/29/02

WKPLOGl.O.# N0204231, N0204232, and N0204233 RECEIVED DATE 4/29/02

Contract #; WTC AR2 analysis date 4/3CTO2

REPORT DATE 4/30/02 CLIENT JOB: NYC Department of Environmental Protection CLIENT JOB #; 1079,01.01 LOCATION S.W. /kreaf Site Map ANALYSIS; AIRBORNE FIBER COUNTING. PHASE CONTRAST MICROSCOPY, NIOSH 7400.I. NIOSH PAT Lab NO. 07186; NY COLLECTION DEVICE: 25 mm MCE Filter Cassette; Collection Area = 335 sq mm;

SAMPLE WERE COLLECTED BY; Festy Osemwegie, J- Garcia, and E, Drbra

SUMMARY OF ANALYSIS

CLIENT FIBERS/ FIBERS/ sample# Site# SAMPLE LOCATION Vol. sq mm cc

27 Gateway Plaza Park Area 675 0.00 <0.004 1079.01.01 001 002 31 South End Ave. and Albany Street 675 2.50 <0.004 West Street and Albany Place 67S 0.00 <0.004 003 32 004 33A Rector Place by the Park Place 675 0.00 <0.004

005 34 W. Thames Street - Along Waterfront 675 0.00 <0.004

006 37 West of Third Place 675 0.00 <0.004

007 8 West Street and Warren Street 67S 1.30 <0.004

4 River Terrace and Chambers Street 676 0.00 <0.004 006 008 CA River Terrace Park Area Between Park Piece and Warren Street 676 0.00 <0.004 River Terrace and Park Place West 675 1.30 <0.004 010 9 River Terrace and Vesey 0.00 <0.004 oil 17 676 7 Warren Street and North End Avenue 675 0.00 <0.004 012 North End Avenue Park place West 675 0.00 <0.004 013 10 014 29 Trinity Place and Thames Street 675 1.30 <0.004 Fulton and Church Street 67S 0.00 <0.004 015 21 Vesey Street and West Broadway 675 0.00 <0.004 016 20A 017 16 Park place and Church Street 675 0.00 <0.004

12 Murray Street and Church Street 675 0.00 <0.004 010 Park Place and Greenwich Street 67S 0.00 <0.004 019 15 020 11 Murray Street and Greenwich Street 675 0.00 <0.004

021 Field Blank 0.00 022 Field Blank 0.00

NOTES; 1. S.5 fibers/100 fields was used to calculate the limit of detection (LOD). 2. Samples were not collected by WKP Laboratories, Inc, 3, The Federal EPA Clearance Critical following an asbestos abatement project is 0.010 fibers/cc. 4. PCM air samples wHi be disposed of after 3 months unless otherwise directed by client in writing.

Louis Lombardi

laboratory analyst laboratory director

NYC-WTC_000161812

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000161812Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000161610 · Box DEP Box 42

A single-page air quality data sheet from the Department of Environmental Protection regarding the World Trade Center site.

Filed in the same folder

Compare copies and versions →