WKP
LABORATORIES, INC
AIR SAMPLE-ANALYSIS REPORT
PHASE CONTRAST MICROSCOPY
CLIENT; WARREN & PANZER ENGINEERS. P.O. TURNAROUND TIME 24HRS
WKP FILE# 501-01 SAMPLE DATE 4/9/02
WKPLOGI.D.# NQ20449 RECEIVED DATE 4»/02
Centrad#: WTCAR2 analysis date 4/10/02
REPORT DATE 4/10/02
CLIENT JOB: NYC Department el Environmental Protection
CUENTJOB#: 1079.01.01
LOCATION S.W. Area/Site Map
AIRBORNE FIBER COUNTING. PHASE CONTRAST MICROSCOPY, NIOSH 7400. NIO8H PAT Lab
ANALYSIS:
NO. 07186; NY STATE ELAP Lab NO. 11251.
COLLECTION DEVICE; 25 mm MCE Filter Caseette; CoBecBon Area o 385 aq mm;
i.
ReW Area =■ 0,00763 sq mm.
SAMPLE WERE COLLECTED BY: Lawrence Baer
SUMMARY OF ANALYSIS
CUENT VOLUME FIBERS/ FIBERS/
SAMPLE# Site# SAMPLE LOCATION (LITERS) sqmm cc
1079.01.01 001 Field blank 0.0
002 Field Blank 0.0
003 27 Gateway Plaza Park Area 075 6.4 0.0O4
004 31 South End Ave. and Albany Street 67S 8.9 0.005.
005 32 Vitest Street end Albany Place 675 6.4 0.004
006 33A Rector Place by the Park Place 673 10.2 0,006
007 34 W. Thames Street • Along Waterfront 675 3.6 <0.004
008 37 West of Third Place 675 8.9 0.005
NOTES: 1.5,5 Bbera/lOO fields was used to calculate the Umil of detection (LCD). Results below the LOO have no statistical validity.
2. Samples were net collected by WKP Laboratories. Inc.
3. The Federal EPA Clearance Critical following an ashaatos abatement project Is 0.010 fibers/cc.
4. PCM air samples tMlI be diapoaed of after 3 months unless otherwise directed by dient In writing.
DM
LABORATORY ANALYST laboratory director
NYC-WTC_000161717