NYC 9/11 Public Portal Document
WKP
LABORATORIES, INC
AIR SAMPLE ANALYSIS REPORT
PHASE contrast microscopy
CLIENT: WARREN a PANZER ENGINEERS, P.C. TURNAROUND TIMg 24HRS
WKP FILE# 301-01
SAMPLE DATE 4/11/02
WKPLOGI.D.# N0204G2, N020403, N080404
RECEIVED DATE 4/11/02
Contract#: WTCAR2
ANALYSIS DATE 4/12/02
REPORT DATE 4/12/02
CLIENT JOE: NYC Department ot Environmental Protection
CLIENT JOB#: 107B.01.01
LOCATION WTC Sampling-NYC
ANALYSIS: AIRBORNE FIBER COUNTING, PHASE CONTRAST MICROSCOPY, NIO3H 7400. NIOSH PAT Lab
NO. 071B6; NY STATE ELAP Lab NO. 11281.
COLLECTION DEVICE: 23 mm MCE Filter Cassatts; Collection Area » 3BS sq mm;
Field Area » 0.00785 sq mm.
SAMPLE WERE COUECTEO BY; Lawrence Baer, Benny Giamhnana, and J. Garcia
SUMMARY OF ANALYSIS
CLIENT VOLUME FIBERS/
SAMPLE# Sita# SAMPLE LOCATION (LITERS) sq mtn FIBERS/ co
1079.01.01 001 Field Blank 0.0
002 Raid Blank 0.0
006 27 Gateway Plaza Park Area ore 0.0 <6.004
004 31 South End Ave. and Albany Street 673 7.6 0.004
003 32 West Street and /Ubany Place 673 1.9 <O.004
006 33A Rector Place by the Park Place 67S 4.5 <0.004
007 34 W.Thamee Street-Along Waterfront 678 12.7 0.007
006 37 West of Third Place 67S 6.4 0.004
OOB B West Street and warren Street 676 6.1 <0.004
010 4 River Terrace and Chambers Street 676 1.3 <0.004
Oil 6A River Terrace Park /Vaa Between Park Place and Warren Street S7S 7.6 0.004
012 6 River Terrace and Park Place West 675 7.6 0.004
013 17 River Tarraoe and Vesey 876 10.2 0.006
014 7 Warren Street and North End Avenue B7S 6.1 <0.004
013 10 North End Avenue Park plaoa West 67S 10.2 0.006
016 26 Trinity Place and Thames Street 678 13.4 0.006
017 21 Fulton and Church Street 673 14.6 0.008
018 20A Vesey Street and West Broadway 675 15.3 O.ODB
019 16 Park place and Church Street 675 6,1 <0.004
020 12 Murray Street and Church Street 675 15.8 0.000
021 IS Park Place and Greenwich Street 675 3.1 <0J)04
022 11 Murrey Street and Greenwich Street 675 B.3 0.005
NOTES; 1.6.5 <lbar</lOO fields was used to oatouiaie the limit er detection (LOD). Results below (he LOO have ne statislicai vaiwiiy,
2. Samples ware net eelleeted by WKP Laboratories. Inc.
9. The Fedemi EPA Clearance CrWcel foiewing an asbestos abatomont project Ie 0.010 fibere/cc.
PCM air samples win be diepesed e( etter 3 months unless otherwise dlrscted by client In writing.
David Multokandov
LABORATORY ANALYST LABORATORY DIRECTOR