AIR SAMPLE ANALYSIS REPORT
PHASE CONTRAST MICROSCOPY
CLIENT: WARREN & PANZER ENGINEERS, P.O. TURNAROUND TIME 24HRS
WKPFILE# 501-01 SAMPLE DATE 4/11/02
WKP LOG I.D. # N020462, N020463, N020464 RECEIVED DATE 4/11/02
Contract #: WTCAR2 ANALYSIS DATE 4/12/02
REPORT DATE 4/12/02
CLIENT JOB: NYC Department of Environmental Protection
CLIENT JOB #: 1079.01.01
LOCATION WTC Sampling- NYC
AIRBORNE FIBER COUNTING, PHASE CONTRAST MICROSCOPY, NIOSH 7400. NIOSH PAT Lab
ANALYSIS:
NO. 07186: NY STATE ELAP Lab NO. 11251.
1 cnTiriM ncx/inc. 25 mm MCE Filter Cassette: Collection Area = 385 sq mm:
COLLECTION DEVICE. 0.00785 sq mm.
SAMPLE WERE COLLECTED BY: Lawrence Baer, Benny Giambnone, and J. Garcia
SUMMARY OF ANALYSIS
CLIENT VOLUME FIBERS/
SAMPLE# Site# ____________ SAMPLE LOCATION (LITERS) sq mm FIBERS/ cc
1079.01.01 001 Field Blank 0.0
002 Field Blank 0.0
003 27 Gateway Plaza Park Area 675 0.0 <0.004
004 31 South End Ave. and Albany Street 675 7.6 0.004=’
005 32 West Street and Albany Place 675 1.9 <0.004
006 33A Rector Place by the Park Place 675 4.5 <0.004
007 34 W. Thames Street - Along Waterfront 675 12.7 0.007<«!’
008 37 West of Third Place 675 6.4 0.004-S’
009 8 West Street and Warren Street 675 5.1 <0.004
010 4 River Terrace and Chambers Street 675 1.3 <0.004
oil 6A River Terrace Park Area Between Park Place and Warren Street 675 7.6 0.004
012 9 River Terrace and Park Place West 675 7.6 0.004<s*
013 17 River Terrace and Vesey 675 10.2 0.006 «•
014 7 Warren Street and North End Avenue 675 5.1 <0.004
015 10 North End Avenue Park place West 675 10.2 0.006
016 29 Trinity Place and Thames Street 675 13.4 0.008'®'
017 21 Fulton and Church Street 675 14.6 0.008
018 20A Vesey Street and West Broadway 675 15.3 0.009
019 16 Park place and Church Street 675 5.1 <0.004
020 12 Murray Street and Church Street 675 15.9 0.009««*’
021 15 Park Place and Greenwich Street 675 5.1 <0.004
022 11 Murray Street and Greenwich Street 675 8.3 0.005 <s8>
NOTES: 1. 5.5 tibera/100 fields was used to calculate the limit of detection (LOD). Results below the LOD have no statistioal validity.
2. Samples were not collected by WKP Laboratories, Inc.
3. The Federal EPA Clearance Critical following an asbestos abatement project is 0.010 fibers/cc.
PCM air samples will be disposed of after 3 months unless otherwise directed by client In writing.
David Mullokandov
LABORATORY ANALYST LABORATORY DIRECTOR