NYC 9/11 Public Portal Document
WKP
laboratories, INC
AIR SAMPLE ANALYSIS REPORT
PHASE CONTRAST MICROSCOPY
CUENT: WARREN & PANZER ENGINEERS. P.C. • TURNAROUND TIME 24HRS
WKP PILE# S01-01 SAMPLE DATE A/6/02
WKP LOG I.D, # N02C446
RECEIVED DATE 4/8/02
Convaet* WTCAR2 ANALYSIS DATE 4/0rtl2
REPORT DATE 4/9A)2
CUENT JOB: NYC Department of Environmental Proledion
CLIENT JOB#; 1079.01.01
LOCATION WTC Sampling
ANALYSIS: AIRBORNE FIBER COUNTING, PHASE CONTRAST MICROSCOPY, NIOSH 7400. NIOSH PAT Lab
NO. 07168; NY STATE ELAP Lab NO. 11251,
COLLECTION DEVICE: 25 mm MCE Filter Cassette; Collection Area » 395 sq mm;
Field Area = 0,00785 sq mm.
SAMPLE WERE COLLECTED BY: Fesiy Osemw^te
SUMMARY OP ANALYSIS
CLIENT VOLUME FIBERS/ FIBERS/
S/WIPLE# Site# SAMPLE LOCATION (LITERS) sqmm co
T
1079.01.01 001 Inlaid Blank ' 0.0
002 Field Blank 0.0
003 29 Trlrtiiy Place and Thames Street 675 5.1 <0,004
004 21 Fulton and Chord, Street 678 6.1 <0,004
005 20A Vesey Street and West Broadway 67S 11.5 0,007
006 18 Park place and Church Street STS 10.9 0.006
007 12 Murray Street and Church Street 675 14,0 0.008
008 18 Park Place and Greenwich Street 675 10.2 0,006
009 11 Murray Street and Greenwich Street 67S 12.7 0.Q07
NOTES; 1.5.5 fibera/100 fields was used to calculate the Smit of detection (LOD), Reaulte below the LOD have no stsrtistical validity.
2. Samples were not collected by WKP Laboratories, Ino.
3. The Federal EPA Clearance Critical following an asbestos abaternerit project is 0,010 ^bers/cc.
4. PCM air samples will be disposed of alter 3 months unless otherwise dlrsded by client in writing.
DM
LABORATORY ANALYST LABORATORY DIRECTOR
NYC-WTC_000161724