AIR SAMPLE ANALYSIS REPORT
PHASE CONTRAST MICROSCOPY
CU6NT: WARREN & PANZER ENGINEERS. P.O. TURNAROUND TIME 24HRS
WKP FILS# 501-01
SAMPLE DATE 4/d/02
WKPL06I.D.* N020450 RECEIVED DATE 4/9/02
Contract#; WrCAR2
ANALYSIS DATE 4/10/02
REPORT DATE 4/10/02
CLIENT JOB; NYC Department of Environmental Protection
CLIENT JOB#: 1079.01.01
LOCATION WrC Sampling
ANALYSIS: AIRBORNE FIBER COUNTING. PHASE CONTRAST MICROSCOPY. NIOSH 7400. NIOSH PAT Lab
NO. 07186; NY STATE ELAP Lab NO. 11251.
COLLECTION DEVICE; Cassette; Collection Area = 385 sq mm;
Field Area « 0.0076S sq mm.
SAMPLE WERE COLLECTED BY: J. Garcia
SUMMARY OF ANALYSIS
CLIENT VOLUME FIBERS/ FIBERS/
SAMPLE# Site# SAMPLE LOCATION (LITERS) sq mm cc
1079.01.01 001 11 Murray Street and Greenwieli Street 675 7.6 0.004
002 12 Murrsor Street and Church Street 675 12.1 0.007
003 1S Park Place and Greenwieh Street 675 12.7 0.007
004 16 Park place and Church Street 675 B.9 0.O0S
005 20A Vesey Street and West Broadway 678 14,0 o.ooa
006 21 Fulton and Church Street 675 6.9 0.005
007 28 Tiiniy Place and Thames Street 67S 6.4 0.004
NOTES; 1. S.S fibers/lOO fields was used to calculate the limit of detection (LOO). Results below the LOd have no statistical validity.
2. Samples were net collected by WKP Laboratories, Ino.
3. The Federal EPA Clearance Critical following an asbestos abatement project is 0.010 fibers/cc.
4. PCM air samples will be disposed of after 3 months unless othenvise directed by client In writing.