LABORATORIES, INC
AIR SAMPLE ANALYSIS REPORT
PHASE CONTRAST MICROSCOPY
CLIENT: WARREN & PANZER ENGINEERS, P.C. TURNAROUND TIME 24HRS
WKPFILE# 501-01 SAMPLE DATE 4/10/02
WKPLOGI.D.# N020459 RECEIVED DATE 4/10/02
Contract #: WrCAR2 ANALYSIS DATE 4/11/02
REPORT DATE 4/11/02
CLIENT JOB; NYC Department of Environmental Protection
CLIENT JOB#: 1079.01.01
LOCATION S.W. Area/ Site Map
AIRBORNE FIBER COUNTING, PHASE CONTRAST MICROSCOPY, NIOSH 7400. NIOSH PAT Lab
ANALYSIS:
NO. 07186; NY STATE ELAP Lab NO. 11251.
25 mm MCE Filter Cassette; Collection Area = 385 sq mm;
COLLECTION DEVICE:
Field Area = 0.00785 sq mm.
SAMPLE WERE COLLECTED BY: Lawrence Baer
SUMMARY OF ANALYSIS
CLIENT VOLUME FIBERS/
SAMPLE# Site# SAMPLE LOCATION (LUEBS) sq mm FIBERS/ cc
1079.01.01 001 Field Blank 0.0
002 Field Blank 0.0
003 27 Gateway Plaza Park Area 675 3.8 <0.004
004 31 South End Ave. and Albany Street 675 9.6 0.005
005 32 West Street and Albany Place 675 5.1 <0.004
006 33A Rector Place by the Park Place 675 3.8 <0.004
007 34 W. Thames Street - Along Waterfront 675 7.0 0.004
008 37 West of Third Place 675 3.2 <0.004
NOTES: 1.5.5 fibers/100 fields was used to calculate the limit of detection (LOD). Results below the LOD have no statistical validity.
2. Samples were not collected by WKP Laboratories, Inc.
4. PCM air samples will be disposed of after 3 months unless otherwise directed by client in writing.