specified in HUD Appendix 13.1.

b. Samples must be labeled and accompanied with completed chain of custody forms before shipping to the designated laboratory. The label must include the EPA Project Tracking Number. Samples will be packed sealed and shipped to USEPA Contract Laboratory for analysis. Metals samples will be analyzed using EPA Method SW- 846 6010B. Mercury samples will be analyzed using EPA Method SW-846 7471.

21. Post Clean-up Air Sampling Procedures a. Sampling shall not begin until a visual inspection confirms the absence of visible dust and debris. Post cleaning air sampling shall be completed within 24-hours of the completion of cleaning activities. b. All surfaces must be completely dry prior to the start of sampling. c. Window air conditioning units where applicable shall be run/operated at least 15 minutes prior to the start of sampling. The air conditioning units shall operate continuously throughout the sampling. d. Based on consultation with resident, aggressive or modified aggressive air sampling will be conducted upon completion of cleaning. Before the start of sampling, forced air equipment (such as a 1 horsepower electric leaf blower) may be used to direct exhaust air against walls, ceilings, floors and other surfaces, '^en directing the exhaust, caution shall be taken to minimize disturbance and potential damage to furnishings and personal belongings. e. One 20-inch fan shall be installed per 10,000 cubic feet of room space and run at low speed. The fan shall operate continuously throughout sampling and shall not be turned off until sampling is completed. f. For studio apartments 3 samples shall be collected. For 1-bedroom apartments and above 5 samples shall be collected. Sampling equipment shall be placed in living areas and away from obstructions. The sampling cassette must be placed on a tripod and not taped to existing surfaces. g- Common spaces will be sampled without the use of forced air devices (fans, leaf blowers etc). For small spaces, less than 260 linear feet and 160 square feet, 3 samples will be collected. For large spaces greater than 260 linear feet or 160 square feet and less than 25,000 square feet 5 samples will be collected. For spaces greater than 25,1 square feet, 1 sample will be collected for each 5,' square feet. Sampling equipment shall be placed away from obstructions. The sampling cassette must be placed on a tripod and not taped to existing surfaces. h. Asbestos air samples shall be collected in accordance with the procedures specified in NIOSH Method 7400. Air sampling pumps will be operated at 10 liters per minute for eight (8) hours to achieve the maximum volume requirement of4800 liters. i. Samples must be labeled and accompanied with completed chain of custody forms before shipping to the designated laboratory. The label must include the EPA Project Tracking Number. Samples will be packed, sealed and shipped to USEPA Contract Laboratory for analysis.

6

NYC-WTC_000161179

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000161179Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →