sampling will be conducted. Residents shall not be present in their apartment during
aggressive air sampling activities.
1. Before beginning aggressive air sampling, forced air equipment (such as a 1
horsepower electric leafblower) shall be used to direct exhaust air against walls,
ceilings, floors and other surfaces. When directing the exhaust, caution shall be
taken to minimize disturbance and potential damage to furnishings and personal
belongings.
ii. For modified aggressive air sampling forced air equipment shall not be employed.
iii. All other procedures are identical for aggressive and modified aggressive air
sampling.
b. One 20-inch fan shall be installed per 10,000 Cubic feet ofroom space and run
speed. The fan shall operate continuously throughout sampling and shall not be turned off
until sampling is completed. ; f
c. For studio apartments 3 samples shall be collected. For 1 -bedroom apartments and above
5 samples shall be collected. Sampling equipment shall be placed in living areas and away
fi-om obstructions. The sampling cassettemust be placed on a tripod and not taped to
existing surfeces.
d. Common spaces will be sampled without the use offorced air devices (fans, leafblowers
etc). For small spaces, less than 160 square feet, 3 samples will be collected. For large
spaces greater than 160 square feet and less than25,000 square feet 5 samples will be
collected. For spaces greater than 25,000 square feet, 1 sample will be collected for each
5,000 square feet. Sampling equipment shall be placed away from obstructions. The
sampling cassette must be placed bn a tripod directed downward at a 45 degree angle and
not taped to existing surfaces.
e. Air samples shall be collected in accordance with the procedures specified inNIOSH 7400
Method for PCM and 7402 for TEM. Air sampling cassettes need to be monitored to
ensure pumps are not clogging by monitoring flow rates. The minimum sample volume
required is 3600 liters.
f. Wipe samples will be collected at 10 percent ofthe residences where sampling only has
been requested^ up to a maximum of50 units, as instructed by EPA. This sampling will
consist of the collection of one wipe sample each for dioxin, total metals and
mercury (a separate wipe sample is required for each parameter). Metalsand
mercuiy wipe samples will be collected in accordance with procedures specified in
HUD Appendix 13.1. Dioxin wipe samples will be collected in accordance with the
procedures specified in ASTMD 6661-01.
g- The contractor shall document all the necessary information regarding sampling activities,
fill out all field logs, data sheets, and chain-of-custody forms. The contractor shall use F2L
for all sample and chain-of-custody documentation. Samples must be labeled and
accompanied with completed chain-of-custody forms before shipping to the designated
laboratory. The label must include the EPA Project Tracking Number. Samples will be
packed, sealed and shipped to EPA Contract Laboratory for analysis.
h. All information must be maintained using the secure EPA website (url, user name and
password to be provided by EPA). Dates for monitoring and/or cleaning shall be provided
NYC-WTC_000138686
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000138686Source: NYC Law Department, mirrored locally
EPA transmits revised statements of work for WTC cleaning and monitoring activities incorporating modifications and additions discussed in interagency meeting.
DEP memo documenting closure of environmental assistance desk following decline in public inquiries about water quality, air quality, asbestos, and dust.