21 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Electronic dioxin report submission for 125 Cedar Street, Dec 2002
Machine-extracted title · confidence 95%Correspondence regarding the final electronic report and TEQ calculations for dioxin data collected at 125 Cedar Street.
NYC-WTC_000156813–000156832Folder label: “125 CEDAR STREET”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Final Report 125 Cedar Street, NYC, NY
Air Monitoring
Sample Collection ATC collected samples of air on 25 millimeter, mixed-cellulose ester filter membranes (0.45 micron pores) contained in manufacturer pre-assembled, three-piece cassettes with electrically conductive, extended cowls. Pump flow rates were determined (both at the start and at the end of the sampling period and periodically by a representative of the NYCDEP) with a secondary standard (rotameter) that is calibrated quarterly against a primary standard (Gilian Instrument Corporation primary flow calibrator “Gilibrator”). Fibers from ambient air were collected with the filter cassette open-faced and positioned between three to five feet above the floor. Sample Analysis PCM ambient and clearance samples were analyzed by ATC’s New York City laboratory utilizing the PCM method of analysis. The microscope used for sample analysis was equipped with a phase contrast condenser. Sizing and fiber counts were performed at 400X magnification. Samples were analyzed by the National Institute of Occupation Safety and Health (NIOSH) Method 7400 using method “A” counting rules. Method “A” rules count only those fibers that have a length greater than five microns and a length-to- width ratio greater than three-to-one. All air sample results are reported in fibers per cubic centimeter of air (f/cc). TEM ambient air samples were analyzed by ATC’s New York City laboratory under strict AHERA protocol. TEM with Energy Dispersive X-ray analysis (EDX) involves subjecting the prepared filter media to a stream of electrons. The returning diffraction pattern is a signature for the elemental composition of the material. This allows for precise asbestos quantification. Quality Assurance Analysis was performed by personnel who have completed the NIOSH 582 Sampling and Evaluating Airborne Asbestos Dust course or an equivalent course. Personnel also participate in the NIOSH/AIHA (American Industrial Hygiene Association) Proficiency Analytical Testing (PAT) Program to ensure consistency in methodology. All laboratory technicians involved in air sample analysis have received applicable EPA training.
Air Sample Results Final air clearance samples reported concentrations of airborne fibers less than the concentrations required by the EPA for this project. The attached appendices contain all laboratory analysis information.
ATC Project No. 15.22906.0002 Pages
NYC-WTC_000156821
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
No available related records indexed in this group.
Filed elsewhere
21 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗19 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107585
Laboratory data table listing analytical results for various dioxin and dibenzofuran compounds with detection limits.
20 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000129376
Volume 1 of the final documentation report for the WTC unoccupied building monitoring program at 125 Cedar Street.
19 shared non-person entities · 1 shared topics · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120991
Record documenting the transfer and custody of air samples from Building #100 at 345 South End Avenue collected on October 22, 2001.
8 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120940
Document tracking environmental samples collected from Building #100 at 345 South End Avenue on October 22, 2001.
8 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000119908
Record documenting the transfer and custody of air samples from 365 South End Avenue collected on October 17, 2001.
7 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000176247
Comprehensive environmental assessment report prepared by TRC Engineers for the New York City Law Department.
13 shared non-person entities · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121462
Record documenting the transfer and custody of air samples from Building #500 at 385 South End Avenue collected on October 22, 2001.
8 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121409
Document tracking environmental samples collected from Building #500 at 385 South End Avenue on October 22, 2001.
8 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000119863
Document tracking environmental samples collected from 365 South End Avenue on October 17, 2001.
7 shared non-person entities · 1 shared topics · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107585
Laboratory data table listing analytical results for various dioxin and dibenzofuran compounds with detection limits.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.981 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000129376
Volume 1 of the final documentation report for the WTC unoccupied building monitoring program at 125 Cedar Street.
Similarity score 0.977 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000129376
Volume 1 of the final documentation report for the WTC unoccupied building monitoring program at 125 Cedar Street.
Similarity score 0.974 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Buildings in this record
Machine-extracted building matches; verify each source. Buildings, never households.
- 125 Cedar Street · 7 pages · confidence 0.85 · verify page 6
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000107585
Laboratory data table listing analytical results for various dioxin and dibenzofuran compounds with detection limits.
Cited alongside this record in an Ask answer
Volume 1 of the final documentation report for the WTC unoccupied building monitoring program at 125 Cedar Street.
Cited alongside this record in an Ask answer
Formal request by a resident for the Department of Environmental Protection to perform cleaning and monitoring work at their apartment.
Cited alongside this record in an Ask answer
NYC-WTC_000097066
Notice of a mandatory pre-bid meeting and scope for asbestos abatement at 125 Cedar Street in August 2002.
Cited alongside this record in an Ask answer
NYC-WTC_000107194
Mandatory pre-bid meeting notice for asbestos abatement and cleaning at 125 Cedar Street scheduled for August 28, 2002.
Cited alongside this record in an Ask answer