machine-extracted · confidence unavailable · Check page ↗Final Report Volume 1, WTC Unoccupied Building Monitoring, 125 Cedar
Machine-extracted title · confidence 95%Volume 1 of the final documentation report for the WTC unoccupied building monitoring program at 125 Cedar Street.
NYC-WTC_000129376–000129386
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Final Report 125 Cedar Street, NYC, NY
• Asbestos Asbestos clearance air samples were analyzed via Transmission Electron Microscopy (TEM) utilizing the USEPA's PCMe method of structure counting. PCMe
TEM ambient air samples were analyzed by ATC's New York City laboratory under strict AHERA protocol. TEM with Energy Dispersive X-ray analysis (EDX) involves subjecting the prepared filter media to a stream of electrons. The returning diffraction pattern is a signature for the elemental composition of the material. This allows for precise asbestos quantification.
Silica A suspension of the sample particulate in tetrahydrofuran (THF) is created by dissolving the sample filter in THE and then sonicating. The sample particulate is then deposited onto a silver membrane filter and analyzed by X-ray diffraction giving a series of diffraction peaks (lines) occurring at different angles relative to the sample and X-ray source. These specific peaks are indicative of elemental silica and can be quantified.
Quality Assurance 40 Analysis was performed by personnel who have completed the NIOSH 582 Sampling and Evaluating Airborne Asbestos Dust course or an equivalent course.
Personnel also participate in the NIOSH/AIHA (American Industrial Hygiene Association) Proficiency Analytical Testing (PAT) Program to ensure consistency in methodology. All laboratory technicians involved in air sample analysis have received applicable EPA training.
Air Sample Results
Final air clearance samples reported concentrations of airborne fibers less than the concentrations required by the USEPA for this project.
The clearance air sampling criteria for each of the following analytes were achieved in accordance with project specifications.
• Asbestos in air, 0.0009 f/cc PCMe • Fibrous glass in air, <0.01 f/cc • Crystalline silica in air, 0.5 µg/m3 • Mercury, between 1 and 2 mg/m2
ATC Project No. 15.22906.0002 Page 6
NYC-WTC 000129383
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
No available related records indexed in this group.
Filed elsewhere
19 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗19 shared non-person entities · 1 shared topics · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107585
Laboratory data table listing analytical results for various dioxin and dibenzofuran compounds with detection limits.
19 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149432
DEP asbestos project notification form and inspection report dated December 12, 2002.
15 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117536
Chain of custody documentation for bulk sampling and air monitoring at 345 South End Avenue Building 100.
7 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117668
Chain of custody documentation for bulk sampling and air monitoring at 385 South End Avenue Building 500.
6 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107393
Document outlining mandatory pre-bid meeting and scope for asbestos abatement contractor work at a WTC building.
13 shared non-person entities · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117493
Cover page for a report detailing annual assessment, bulk sampling, and air monitoring activities at the specified address.
7 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000163360
Technical specifications for air quality monitoring work at two Manhattan buildings.
14 shared non-person entities · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗12 shared non-person entities · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗12 shared non-person entities · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Buildings in this record
Machine-extracted building matches; verify each source. Buildings, never households.
- 120 Liberty Street · 1 pages · confidence 0.00 · verify page 1
- 125 Cedar Street · 9 pages · confidence 0.85 · verify page 8
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Similar indexed content
Similar indexed content
Similar indexed content
NYC-WTC_000107585
Laboratory data table listing analytical results for various dioxin and dibenzofuran compounds with detection limits.
Similar indexed content
DEP asbestos project notification form and inspection report dated December 12, 2002.
Similar indexed content