Final Report 125 Cedar Street, NYC,NY
AIR MoNrroRING
Sample Collection
ATC collected samples of air on 25 millimeter, mixed-cellulose ester filter membranes (0.45 micron pores) contained in manufacturer pre-assembled, three-piece cassettes with electrically conductive, extended cowls. Pump flow rates were determined (both at the start and at the end of the sampling period and periodically by a representative of the NYCDEP) with a secondary standard (rotameter) that is calibrated quarterly against a primary standard (Gilian Instrument Corporation primary flow calibrator "Gilibrator"). Fibers from ambient air were collected with the filter cassette open-faced and positioned between j.five feet above the floor.
Sample Analysis
PCM ambient and clearance samples were analyzed by ATC's New York City laboratory utilizing the PCM method of analysis. The microscope used for sample analysis was equipped with a phase contrast condenser. Sizing and fiber counts were performed at 400X magnification. Samples were analyzed by the National Institute of Occupation Safety and Health (NIOSH) Method 7400 using method "A" counting rules. Method "A" rules count only those fibers that have a length greater than five microns and a length-to- width ratio greater than three-to-one. All air sample results are reported in fibers per cubic centimeter of air (f/cc).
TEM ambient airsmples were analyzed by ATC's New York City laboratory unde ct , IERA _pro . TEM with Energy Dispersive X-ray analysis (EDX) involves subjecting the prepared filter media to a stream of electrons. The returning diffraction pattern is a signature for the elemental composition of the material. This allows for precise asbestos quantification.
Quality Assurance
Analysis was performed by personnel who have completed the NIOSH 582 Sampling and Evaluating Airborne Asbestos Dust course or an equivalent course.
Personnel also participate in the NIOSH/AIHA (American Industrial Hygiene Association) Proficiency Analytical Testing (PAT) Program to ensure consistency in methodology. All laboratory technicians involved in air sample analysis have received applicable EPA training.
Air Sample Results
Final air clearance samples reported concentrations of airborne fibers less than the concentrations required by the EPA for this project. The attached appendices contain all laboratory analysis information.
ATC Project No. 15.22906.0002 Page 5
NYC-WTC 000107593
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
No available related records indexed in this group.
Filed elsewhere
20 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗20 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120940
Document tracking environmental samples collected from Building #100 at 345 South End Avenue on October 22, 2001.
8 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120991
Record documenting the transfer and custody of air samples from Building #100 at 345 South End Avenue collected on October 22, 2001.
8 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000129376
Volume 1 of the final documentation report for the WTC unoccupied building monitoring program at 125 Cedar Street.
19 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000119908
Record documenting the transfer and custody of air samples from 365 South End Avenue collected on October 17, 2001.
7 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121462
Record documenting the transfer and custody of air samples from Building #500 at 385 South End Avenue collected on October 22, 2001.
8 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000119863
Document tracking environmental samples collected from 365 South End Avenue on October 17, 2001.
7 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000114019
Letter and chain of custody document tracking HVAC and environmental inspection samples from 333 Rector Place.
7 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121409
Document tracking environmental samples collected from Building #500 at 385 South End Avenue on October 22, 2001.
8 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149798
Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.
13 shared non-person entities · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Buildings in this record
Machine-extracted building matches; verify each source. Buildings, never households.
- 125 Cedar Street · 9 pages · confidence 0.85 · verify page 6
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Similar indexed content
Similar indexed content
Similar indexed content
Document tracking environmental samples collected from Building #100 at 345 South End Avenue on October 22, 2001.
Similar indexed content
Record documenting the transfer and custody of air samples from Building #100 at 345 South End Avenue collected on October 22, 2001.
Similar indexed content