NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 38/No folder label
Document / 22 pages

Dioxin and dibenzofuran analysis data, Sep 2002

Machine-extracted title · confidence 85%

Laboratory data table listing analytical results for various dioxin and dibenzofuran compounds with detection limits.

NYC-WTC_000107585–000107606
Page image
Scanned page image, NYC-WTC_000107592
OCR text

OCR status: ok · source: pdftotext

NYC 9111 Public Portal Document

Final Report 125 Cedar Street, NYC, NY

■ Collected and analyzed final air clearance samples (ATC). ■ Collected and analyzed final wipe clearance samples (ATC). ■ Disassembled and cleaned work area (Action).

Engineering Controls

Ac ion employed the following engineering controls during the removal of all ACM frd'm the work areas:

■ Isolated each work area per Contract Documents, and to the satisfaction of the on- site Project Monitor. ■ Constructed a three-stage decontamination unit with shower. ■ Installed HEPA-filtered negative pressure exhaust fans. ■ Engineering controls were inspected by ATC for compliance with all applicable local, state, and federal rules and regulations.

Work Procedures

Measures to minimize the release of fibers during cleaning included:

■ Wetting of settled dust with water prior to disturbing. ■ Promptly placing removed settled dust in plastic bags for proper disposal.

Worker Protection

Workers who entered the work area during cleaning activities wore disposable protective clothing (Tyvek suits) and proper respiratory protection including Y2 face rosptars air purifying respirators with High Efficient Particulate Air (HEPA) filters.

Decontamination

Workers performed proper decontamination upon exiting each work area by:

■ Removing and disposing of protective clothing. ■ Removing and Rinsing respirator. ■ Showering. ■ Donning street clothing.

Disposal

Action placed asbestos-containing wast9. material in doubled and labeled impermeable plastic bags and transported them to enclose olyethy7ene sheeting ' `dumpsters I for pickup and disposal.

ATC Project No. 15.22906.0002 Page 4

NYC-WTC 000107592

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000107592Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000120991 · Box DEP Box 48

Record documenting the transfer and custody of air samples from Building #100 at 345 South End Avenue collected on October 22, 2001.

Similar indexed content

Compare copies and versions →