21 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗125 CEDAR STREET
Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000156813–000156832
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Final Report 125 Cedar Street, NYC, NY
Collected and analyzed final air clearance samples (ATC). ■ Collected and analyzed final wipe clearance samples (ATC). Disassembled and cleaned work area (Action).
Engineering Controls
Acction employed the following engineering controls during the removal of all ACM from the work areas:
■ Isolated each work area per Contract Documents, and to the satisfaction of the on site Project Monitor. ■ Constructed a three-stage decontamination unit with shower. ■ Installed HEPA-filtered negative pressure exhaust fans. Engineering controls were inspected by ATC for compliance with all applicable local, state, and federal rules and regulations.
Work Procedures
Measures to minimize the release of fibers during cleaning included:
Wetting of settled dust with water prior to disturbing. Promptly placing removed settled dust in plastic bags for proper disposal.
Worker Protection
Workers who entered the work area during cleaning activities wore disposable protective clothing (Tyvek suits) and proper respiratory protection including face respirators air purifying respirators with High Efficient Particulate Air (HEPA) filters.
Decontamination
Workers performed proper decontamination upon exiting each work area by:
■ Removing and disposing of protective clothing. ■ Removing and Rinsing respirator. Showering. Donning street clothing.
Disposal
Action placed asbestos-containing waste material in doubled and labeled impermeable plastic bags and transported them to an enclosed polyethylene sheeting lined dumpsters for pickup and disposal.
ATC Project No. 15.22906.0002 Page 4
NYC-VVTC_000156820
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
No available related records indexed in this group.
Filed elsewhere
21 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107585
Laboratory data table listing analytical results for various dioxin and dibenzofuran compounds with detection limits.
20 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000129376
Volume 1 of the final documentation report for the WTC unoccupied building monitoring program at 125 Cedar Street.
19 shared non-person entities · 1 shared topics · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120991
Record documenting the transfer and custody of air samples from Building #100 at 345 South End Avenue collected on October 22, 2001.
8 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120940
Document tracking environmental samples collected from Building #100 at 345 South End Avenue on October 22, 2001.
8 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000119908
Record documenting the transfer and custody of air samples from 365 South End Avenue collected on October 17, 2001.
7 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121462
Record documenting the transfer and custody of air samples from Building #500 at 385 South End Avenue collected on October 22, 2001.
8 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121409
Document tracking environmental samples collected from Building #500 at 385 South End Avenue on October 22, 2001.
8 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000119863
Document tracking environmental samples collected from 365 South End Avenue on October 17, 2001.
7 shared non-person entities · 1 shared topics · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · 1 shared topics · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000095208
Documentation tracking the chain of custody for environmental samples collected from Building #400 at 375 South End Avenue in October 2001.
8 shared non-person entities · 1 shared topics · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Buildings in this record
Machine-extracted building matches; verify each source. Buildings, never households.
- 125 Cedar Street · 7 pages · confidence 0.85 · verify page 6
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Notice from the New York City Law Department instructing staff to preserve original World Trade Center documents for potential legal actions.
Filed in the same folder
Filed in the same folder
Filed in the same folder
Correspondence requesting a formal letter requiring the sealing of firebrick walls at 125 Cedar Street to allow for reoccupancy.
Filed in the same folder
NYC-WTC_000156799
Correspondence documenting contractor actions to remove back panels behind bookshelves for cleaning without damaging shelving units.
Filed in the same folder