48 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗114 LIBERTY 2 OF 2
Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000155460–000155524
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
December 17, 2002 114 LIBERTY STREET REMOVAL OF DUST, DEBRIS, AND CONTAMINATED MATERIALS
3. Establish negative air pressure;
4. Removal and cleaning of non-porous furnishings that are scheduled to be saved (e.g., kitchen cabinets and countertops, bookshelves, etc.);
5. Removal and disposal of all remaining furnishings and appliances;
6. Removal of perimeter gypsum board walls, and any insulation behind the walls;
7. Removal of interior gypsum board walls and ceilings, and any insulation behind the walls. Contractor shall thoroughly HEPA vacuum the back side of any walls that may be scheduled to remain (i.e., bathroom walls that are covered with tiles);
8. Removal of HVAC units and all associated duct work;
9. Removal of pipe insulation and spray-on fireproofing;
10. Removal of all BX electrical cables and any remaining porous materials;
11. Gross cleaning of the entire work area via HEPA vacuuming and wet wiping techniques;
12. Removal of all polyethylene sheeting on the floors;
13. Removal of all exposed hardwood flooring and gross cleaning of the sub-flooring via HEPA vacuuming and wet wiping techniques;
14. Removal of carpeting and cleaning of the underling hardwood flooring via HEPA vacuuming and wet wiping techniques;
15. Fine cleaning of the entire work area;
16. Work area clearance, to be conducted on each foor as they are completed;
17. Installation of hard barriers at elevator doors and stairwells, to isolate the work area once it has passed clearance testing, from the rest of the building;
18. Cleaning and clearance sampling of the elevators, the elevator shaft (including the top of the elevator cars and the elevator pit), and the stairwells;
19. Removal of all isolation barriers and breaking down of the personal and waste decontamination units.
D. This project will commence once the tenants have removed any necessary materials, items, etc. from their floors. Whatever remains on the floors will be discarded by the contractor, unless explicitly designated by the tenant (in writing to the' er).to remain. _ _
E. All Work will be performed in accordance with applicable asbestos regulations including, but not limited to, the Rules of the City of New York Title 15, Chapter 1 (specific use of licensed asbestos handlers is required). The contractor shall file this abatement work with all appropriate agencies, including all fees.
3 ® AMBIENT GROUP, INC.-2002 SUMMARY OF WORK
NYC-WTC_000155468
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
49 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155525
Initial draft of the comprehensive scope of work required to safely clean 114 Liberty Street following environmental damage.
48 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155168
Draft cleaning procedures and contract documentation for 114 Liberty with minor revisions, shared with EPA for review and comment.
8 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000154680
Application form submitted to the Department of Environmental Protection for notification of an asbestos inspection project.
14 shared non-person entities · Same agency, volume and box · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗10 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155394
Transmission of cleanup and environmental monitoring documentation for 114 Liberty post-WTC dust remediation project.
10 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
NYC-WTC_000138892
Forwarding draft cleaning procedures for 114 Liberty Street to EPA for review and comments.
8 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗8 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗10 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗10 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗10 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Buildings in this record
Machine-extracted building matches; verify each source. Buildings, never households.
- 114 Liberty Street · 9 pages · confidence 0.15 · verify page 1
- 114 UBERTY ST · 1 pages · confidence 0.15 · verify page 2
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Cited alongside this record in an Ask answer
NYC-WTC_000134132
US EPA Region 2 letter dated November 15, 2005, confirming completion of environmental review for abatement plans at 133-135 Greenwich Street.
Cited alongside this record in an Ask answer
NYC-WTC_000155525
Initial draft of the comprehensive scope of work required to safely clean 114 Liberty Street following environmental damage.
Cited alongside this record in an Ask answer
Cited alongside this record in an Ask answer
NYC-WTC_000134871
EPA Region 2 letter regarding revised environmental work plan submission for two buildings including asbestos, health, and safety assessment components.
Cited alongside this record in an Ask answer