These comments are also being transmitted to the EPA Office of the Inspector General (OIG), because they augment those charges presented to the OIG in my 7/4/03 report on the WTC clean­ up?

114 Liberty St. Building History Building history prior to 9/11/01

The 114 Liberty St. building is an eleven floor building on the south border of Ground Zero, which dates from the turn of the century, in 1998, the upper 9 floors were converted from office space to residential condominiums. Commercial tenants in the first two and one half floors remained intact during the renovation.

Before the renovation, the upper floors had vinyl asbestos tiles. The ceilings were plastered brick vaults between steel I-beams. The lower floor commercial spaces had and continue to have dropped loose tile grid ceilings. The lower floor commercial spaces have a separate cooling and ventilation system. AU spaces share a steam heating system.

The renovation and conversion to condominiums covered all the floor tiles with new flooring, primarily wood, with some areas of stone or ceramic tiles.

The ceiUng was lowered with drywaU suspended fi-om the original steel beams on the ceiUngs. This created an open space above the suspended ceUing which is used for the return air flow for the ventilation and air conditioning system. Non-asbestos fireproofing was sprayed onto the original ceilings before installing the suspended drywaU.

Damage and contamination caused by the WTC collapse AU of the fi-ont windows, and a few in the rear of the building, were broken by the WTC blast. In the rooms in fi-ont of the building facing Ground Zero, there were inches of WTC dust. Towards the rear of the building, the dust layers were not as thick, with a coating of around % inch or less.

The ventilation system was operating that day, and thus pulled a large amount of dust throughout the system, including the open return air system above the suspended drywaU ceilings. The spaces between the walls of the residential units (drywaU construction using galvanized steel supports) provided an open path to the space above the ceiling. WTC dust penetrated into these waU spaces as well as into the plenum above the ceiling.

There was structural damage on the face of the building approximately 20 feet high by 40 feet wide, where the building was hit by larger pieces of the collapsing WTC. Iron beams were bent, and bricks were loosened. At the center of the damage, there was a hole spanning 3 window widths fi-om floor to ceiling.

NYC-WTC_0001 55265

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000155265Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000091539 · Box DEP Box 68

Raw laboratory sequence file listing pesticide compounds and calibration standards processed in late 2001.

Cited alongside this record in an Ask answer

Compare copies and versions →