Chain of Custody Form Instructions for WTC Building Sampling

Machine-extracted title · confidence 100%

Instructions and sections for collecting sample location data from a specific building interior.

NYC-WTC_000149537–000149682

Folder label: “ATSDR/DHAC_ASTM

Page image
Scanned page image, NYC-WTC_000149645
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Table 10 Summary of Airborne Fibers at Locations Where Only Synthetic Vitreous Fibers (SVF) Were Detected in Settled Surface Dust

Ontdoor Areas in Lower Manhattan Budding Area Asbestos in Dust SVF in Dust (PLM)’ Aggressive Fibers in Air (PLM or TEM)” Sampling® (PCM)"*

18 Outdoor 30% No <0.001 f/cc 24 Outdoor ND* 55% No 0.002 fi'cc 28 Outdoor ND*' 15% No <0.001 f/cc

Common Areas in Lower Manhattan Building Area Asbestos in Dust SVF in Dust (PLM)’’ Aggressive Fibers in Air (PLM or TEM)® Sampling® (PCM)**

2 Common ND* 27% No 0.005 W 7 Common ND* 5% No 0.001 fee 14 Common ND* 5% No 0.003 fi'cc 25 Common No <0.001 fi'cc 26 ComiiKin ND* 5% No 0.004 fi'cc® 28 Common ND* 10% No 0.001 fi'cc

Residential Units in Lower Manhattan Building Area Asbestos in Dust SVF in Dust (PLM)’’ Aggressive Fibers in Air (PLM or TEM)® Sampling® (PCM)**

1 Residence 1 ND* 20% No 0.006 fi'cc® 1 Residence 2 ND^ 20% ■Yes <0.001 fi'cc 2 Residence 1 ND 25% No <0.001 fi'cc 2 Residence 2 ND* 20% Yes 0.002 fi'cc 6 Residence 1 ND*' 15% Yes <0.001 fi'cc 6 Residence 2 15% Yes <0.001 fi'cc 7 Residence 2 ND* 5% No <0.001 fi'cc 10 Residence 1 15% Yes 0.001 fi'cc 10 Residence 2 ND* 10% Yes 12 Residence 1 ND* 5% No 0.001 fi'cc 12 Residence 2 nd’’ 5% Yes <0.001 fi'cc 13 Residence 1 ND 10% Yes 0.003 fi'cc 15 Residence 2 ND* 5% Yes <0.001 fi'cc 18 Residence 1 ND* 30% No 0.002 fi'cc 18 Residence 2 ND* 35% No 0.002 fi'cc 24 Residence 2 ND 10% No 0.005 fi'cc® Residence 1 ND* 5% No <0.001 fi'cc 27 Residence 2 ND*' 10% No <0.001 f/cc a. Value shown is highest of the reported polarized light microscopy (PLM) and transmission electron microscopy (TEM) results for this area. b. SVF = synthetic vitreous fibers. Measured by PLM analysis. c. Aggressive sampling refers to a technique used in some residential units where the vacuum exhaust (used for settled dust sample collection) was used to stir up the settled surface dust before the air sampling began. d. f/cc = the fibers in each cubic centimeter (cc) of air. This is calculated from the number of fibers seen on the air filter and the volume of air pulled through the filter measured in cubic centimeters. e. Scanning electron microscopy (SEM) and TEM results for these air samples are available and shown on Table 8. f. ND = not detected.

61

NYC-WTC_000149645

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000149645Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

DEP WTC General Correspondence Form · Box DEP Box 10

NYC-WTC_000149798

Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.

24 shared non-person entities · Same agency, volume and box · similarity 0.975

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.