Table 9 Siimmarv of Airbome Fibers at Locations Where Asbestos Was Detected in Settled Surface Dust

Ontdoor Areas in Lower Manhattan Building Area Asbestos in Dust SVFinDusl{PLM)‘ Aggressive Fibers in Air (PLMorTEM)’ Sampling's (PCM/

1 Outdoor <1% 22% No 0.001 f'cc

2“ Outdoor 1.3% 28% No 0.003 f'cc

5 Outdoor 3.4% 25% No 0.002 fee

7 Outdoor 1.7% 35% No <0.001 fee

15 Outdoor 1.9% 72% No <0.001 fee

27 OutAxtr <1% 15% No <0.001 fee

Common Areas in Lower Manhattan Building Area Asbestos in Dust SVF in Dust (PLM)" Aggressive Fibers in Air (PLMorTEM)" Sampling‘s (PCM/

4 Common <1% 15% No 0.001 fee

6 Common <1% 10% No <0.001 fee

10 Common 1.5% 20% No 0.002 fee

24 Common <1% 5% No 0.001 fee

27 Common <1% 10% No <0.001 fee

Residential Units in Lower Manhi ittan___________ Building Area Asbestos in Dust SVF in Dust (PLM)’’ Aggressive Fibers in Air (PLMorTEM/ Sampling's (PCM/

4 Residenee 1 <1% 2% Yes <0.001 fee

4 Residenee 2 <1% 5% Yes 0.001 fee

5 Residenee 1 <1% 10% Yes 0.002 fee

5 Residenee 2 <1% 20% Yes <0.001 fee

9 Residenee 1 <1% 2% Yes 0.001 fee

9 Residenee 2 <1% 5% Yes 0.003 fee

11 Residenee 1 <1% ND Yes <0.001 fee

11 Residenee 2 1.5% ND Yes <0.001 fee

15 Residenee 1 <1% ND Yes <0.001 fee

27 Residenee 1 <1% 10% No <0.001 fee

a. Value shown is highest of the reported polarized light microscopy (PLM) and transmission electron microscopy (TEM) results for this area. b. SVF = synthetic vitreous fibers. Measured by PLM analysis. c. Aggressive sampling refers to a technique used in some residential units where the vacuum exhaust (used for settled dust sample collection) was used to stir up the settled surface dust before the air sampling began. d. fee = the fibers in each cubic centimeter (cc) of air. This is calculated from the number of fibers seen on the air filter and the volume of air pulled through the filter measured in cubic centimeters. e. Building 2 also had a co-located dust sample; values represent the highest measured result.

60

NYC-WTC_000149644

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000149644Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

DEP WTC General Correspondence Form · Box DEP Box 10

NYC-WTC_000149798

Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.

24 shared non-person entities · Same agency, volume and box · similarity 0.975

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →