Table 10 Summary of Airborne Fibers at Locations Where Only Synthetic Vitreous Fibers (SVF) Were Detected in Settled Surface Dust

Outdoor Areas in Lower Manhattan Building Area Asbestos in Dust SVF in Dust (PLM)* Aggressive Fibers in Air (PLM or TEM)" Sampling’ (PCM)'*

18 Outdoor ND^ 30% No <0.001 f/cc 24 Outdoor ND^ 55% No 0.002 f/cc 28 Outdoor ND^ 15% No <0.001 f/cc

Common Areas in Lower Manhattan Building Area Asbestos in Dust SVF in Dust (PLM)* Aggressive Fibers in Air (PLM or TEM)" Sampling’ (PCM)'*

2 Common w 27% No 0.005 f/cc’ 7 Common ND*' 5% No 0.001 f/cc 14 Common ND* 5% No 0.003 f/cc 25 Common 5% No <0.001 f/cc 26 Common ND* 5% No 0.004 f/cc’ 28 Common 10% No 0.001 f/cc

Residential Units in l.ower Manhattan Building Area Asbestos in Dust SVF in Dust (PLM)* Aggressive Fibers in Air (PLM or TEM)" Sampling’ (PCM)'*

1 Residence 1 ND* 20% No 0.006 f/cc’ 1 Residence 2 20% Yes <0.001 f/cc 2 Residence 1 ND* 25% No <0.001 f/cc 2 Residence 2 ND* 20% Yes 0.002 f/cc 6 Residence 1 ND* 15% Yes <0.001 f/cc 6 Residence 2 ND* 15% Yes <0.001 f/cc 7 Residence 2 ND* 5% No <0.001 f/cc 10 Residence 1 ND* 15% Yes 0.001 f/cc 10 Residence 2 ND* 10% Yes 0.001 f/cc 12 Residence 1 ND* 5% No 0.001 f/ec 12 Residence 2 5% Yes <0.001 f/cc 13 Residence 1 ND* 10% Yes 0.003 f/cc 15 Residence 2 ND* 5% Yes <0.001 f/cc 18 Residence 1 ND* 30% No 0.002 f/ec 18 Residence 2 35% No 0.002 f/cc 24 Residence 2 ND* 10% No 0.005 f/cc’ 25 Residence 1 1^ 5% No <0.001 f/cc 27 Residence 2 ND* 10% No <0.001 f/cc a. Value shown is highest of the reported polarized light microscopy (PLM) and transmission electron microscopy (TEM) results for this area. b. SVF = synthetic vitreous fibers. Measured by PLM analysis. c. Aggressive sampling refers to a technique used in s ome residential units where the vacuum exhaust (used for settled dust sample collection) was used to stir up the settled surface dust before the air sampling began. d. f/cc = the fibers in each cubic centimeter (cc) of air. This is calculated from the number of fibers seen on the air filter and the volume of air pulled through the filter measured in cubic centimeters. e. Scanning electron microscopy (SEM) and TEM results for these air samples are available and shown on Table 8. f. ND = not detected.

61

CITY_21MC100_011171498

NYC-WTC_000233029

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000233029Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →