Table 6 Summary of Locations With Asbestos or Synthetic Vitreous Fibers (SVF) in Settled Surface Dust Sampling locations that had either asbestos in the dust by PLM or TEM analysis or SVF in the settled surface dust by PLM analysis. Ranges of asbestos and SVF values for each type of location are included. Number of Range of Number of Range of Sampling Locations with Asbestos Found" Locations with SVF Found'" Locations: Total Number of Asbestos in SVF in Settled Surface Dust Lower Locations Sampled"" Settled Surface (% of Manhattan Dust locations (% of locations detected)'’ detected)’’ Asbestos (PLM) = 14 Outdoor Asbestos (TEM) =12 6 <l%-3.4 11 l%-72% SVF (PLM) = 14 (43%) (79%)

Asbestos (PLM) =26 Common Asbestos (TEM) = 25 5 <1%-1.5% 14 5%-27% SVF (PLM) = 26 (19%) (54%)

Asbestos (PLM) = 57 Residential Asbestos (TEM) = 52 10 <1%-1.5% 26 2%-35% SVF (PLM) = 57 (18%) (46%)

Asbestos (PLM) = 29 Whole Asbestos (TEM) = 29 12 <l%-3.4% 21 2%-72% Building SVF (PLM) = 29 (41%) (72%)

Number of Range of Number of Range of Sampling Locations With Asbestos Found" Locations SVF Found Locations; Total Number of Asbestos in With SVF in Settled Comparison Locations Sampled" Settled Surface Surface Dust Buildings Dust (% of (% of locations locations detected)’’ detected)'’ Asbestos (PLM) = 3 Common Asbestos (TEM) = 3 0 None Detected 0 None Detected SVF (PLM) =3 (0%) by PLM or TEM (0%) by PLM

Asbestos (PLM) = 5 Residential Asbestos (TEM) = 4 0 None Detected 0 None Detected SVF (PLM) =5 (0%) by PLM or TEM (0%) by PLM

Notes: a. All dust samples were initially analyzed by polarized light microscopy (PLM). Transmission electron microscopy (TEM) analysis was performed to confirm the absence of asbestos if not detected by PLM analysis. b. The number of locations containing asbestos in dust reflects locations with asbestos detected by either PLM or TEM (reported as <1% or more). The percentage of locations with asbestos detected is calculated from the total number of dust samples. c. The range represents the highest value detected at a location (PLM or TEM). d. The percentage of locations with synthetic vitreous fibers (SVF) detected is calculated from the number of SVF PLM samples. e. Some locations had an additional co-located sample obtained, the range shown considers the highest measured value for each sampling location. f. One residential unit had an extra settled surface dust sample (taken from a window sill), which contained 40% SVF by PLM.

57

CITY_21MC100_011171494

NYC-WTC_000233025

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000233025Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →