Future Progrcu
V
DERTA has surveyed other areas inside the perimeter in an effort to target potential sites
to be opened. DERTA does not believe that it will be possible to clear any other areas
because of the close proximity to ground zero. Major work at ground zero would have to
be completed before we could reassess the feasibility of opening another area.
Perimeter ResulU
Higher levels were detected closer to ground zero probably due to increased work activity
on site. TEM analysis will be performed on samples with levels well above clearance to
ensure perimeter is intact.
10/2/01
Fulton/Church -0.019
Warr«i / North End Ave = 0.009
West Street & Warren - 0.009
NW Gateway Plaza at Park Area - 0.008
South End Ave & Albany = 0.008
West & Albany » 0.009
Rector Place by park “ 0.008
3"* PlaceZWcst End/Watereide - 0.008
West end ofWest Thames “0.009
Park Place & River Terrace = 0.007
River Terrace & Chambers = 0.007
River Tciracc & Warren - 0.007
North End Ave & Park Place West • 0.009
Yesey & River Terrace=0.009
Trinity Place & Thames - 0.016; on 10/01-0.015; on 9/31/01-.076
NYC-WTC_000148763