Legal hold notice for WTC documents, undated

Machine-extracted title · confidence 98%

Notice instructing staff to preserve original World Trade Center documents for potential legal actions against the City.

NYC-WTC_000148192–000148619

Folder label: “AIR ASBESTOS MONITORING REPORTS

Page image
Scanned page image, NYC-WTC_000148604
OCR text

OCR status: ok · source: pdftotext

SciLab Job#: 201101751 Client Name: North Atlantic Laboratories, Inc. Table I P. 03 Summary of Bulk Asbestos Analysis Results NYC-WTC_000148604 01 -; Dr. Bernstein; Work Area Apt. 33F, 200 Rector Place

SciLab Client HG Sample Heat Acid Insoluble Sample Sample# Area Weight Sensitive Soluble Non-Asbestos ** Asbestos To by ** Asbestos % by # Location (gram) Organic c Inorganic % Inorganic % PLM/DS TEM NYC 9/11 Public Portal Document

01 01 0.037 51.35 45.95 2.60 NAD Chrysotile Present WTC Dust, Living Room (INSUFFICIENT SAMPLE TO QUANTIFY.)

FAX NO.

.-

Analyzed by: Glem Massey : Dule Analyzed: 12/4/2001

*NADANSD = ro astesins derscied; NA = not aralyzed; NA/PS = not analyzed / positive step; PLM Stik Astestas Analysis by EPA 600. M4-82-026 pe: 40 CFR. 763 (NVLAP Lab #200545-0) and ELAP PLM AGalysis Protocol 198.1 for New York samples (NYSCOH ELAP Lab # 11480): ELAP TEM Aralysis Protocal 195.4 for regetive NY NOD samples: Note: PLM is not consistently reliable in detecting asbestrs in floor coverings and similar non-friable organically bound materials. TEM is currently the only method that can be used to determine if this material can be considered or treated as con-asbestos-containing in New York State (also see EPA Advisory fer Goor tle. FR 59, 146, 38970, 5/1/94). National Institute of Standards and Technology Accreditation requirements mandate that this report must not be reproduced excep: in full without che approval of the laboratory. This PLM report relates ONLY to the items tested. ATHIAS 102543; VT Cera AL016055 NVA=No Visicz Asbestos

Reviewed By: JAN-25-2002 FRI 09:39 AM

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000148604Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000150106 · Box DEP Box 11

DEP report explaining ambient air monitoring for asbestos and the use of indoor standards to characterize outdoor levels.

Cited alongside this record in an Ask answer

NYC-WTC_000150109 · Box DEP Box 11

Department of Environmental Protection report detailing ambient outdoor air monitoring for asbestos fibers.

Cited alongside this record in an Ask answer