Air Monitoring in Lower Manhattan
TreatmctTt
DEP is monitoring the ambient outdoor air for asbestos. This effort is augmenting ambient air asbestos sampling
being done by the EPA and other state and city agencies. There is currently no outdoor ambient standard for
asbestos. The US and NYC standard for asbestos in community and residential buildings is 0.01 fibers/cubic
centimeter (f/cc) in indoor air. An indoor area which has had asbestos detected and then removed must show that
air samples are at or below the 0.01 f/cc standard before the indoor area can be re-occupied. Although the ambient
QASbfeStOi outdoor air is being monitored, DEP is using this value as a way to characterize the levels of asbestos in the air.
Since the measurement protocol used, phase contrast microscopy (PCM), counts fibers, DEP is also conducting an
Rotes additional analysis for all samples that are above 0.01 ficc. This measurement protocol is called transmission
y^Asbestos electron microscopy (TEM) and counts the number of asbestos fibers in the sample. EPA is reporting their data in
TEMs, and provides a good explanation of the interpretation of the standard that uses this methodology on their
website.
Acoountiibiia',
Results indicate that, as expected, asbestos is present in some of the debris at the site and in areas very close to the
<^Burc3<js site. Between September 28, 2001 and the present, the vast majority of air sampling results outside the security
aw . zone have been below the standards for asbestos in indoor air.
asssgspi, As testing continues, there may be the possibility of occasional short-term increases in levels of asbestos in the air
above the residential standard of 0.01 fi'cc of air. When the measured level for the outdoor ambient air is above
0.01 f/cc, the samples will be analyzed to determine how many of the fibers are actually asbestos fibers.
OHs!a.C§na£
To view recent air monitoring results, click on a sampling location below or on the map (Link, win open in, new browser
window);
■llufonnaaor-
Sampling Site Location
O PEP News
1 West.Broadway and Worth 19 Vesey and West
Street Sheet
2 Broadway and Worth Street 20 Vesey between
Church and
tm Greenwich Street
3 Duane Street and Trimble 20A Vesey and West
riace Broadway
4 River Terrace and
Chambers Street
21 Fulton and Church
Street 3
5 Chamhers^and North End 22 Fulton between
Avenue Churchand
Broadway
6 Greenwich and Chambers 23 Church and Dev
Street
6A y/est end of Warren Strect 24 Liberty_Sttvet and
a
South End Avenue
7 Warren Street and North 25 Liberty and Church
End Avenue Stre^
8 West Street and Warren 26 Liberty and
Street Broadway
8A RiverTerraceJ’ark area 27 Gateway Plaza Park __
between Park Placc and Area SST*/? /
Warren Street
9 River Terrace and Park 28 Washington and
PlaceWest Cedar Street