NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 53/80 WEST STREET Block: 55 Lot: 16 BIN: 1001061 85 West Street, NY Financial Center Marriott, 16-26 Albany Street, 122-130 Washington Street
Document / 129 pages

Document fragment from DEP Box 53 regarding West Street

Machine-extracted title · confidence 60%

Fragmented record associated with the 80 West Street and Financial Center folder in DEP Box 53.

NYC-WTC_000131145–000131273

Folder label: “80 WEST STREET Block: 55 Lot: 16 BIN: 1001061 85 West Street, NY Financial Center Marriott, 16-26 Albany Street, 122-130 Washington Street

Page image
Scanned page image, NYC-WTC_000131213
OCR text

OCR status: ocr · source: ours

NYC-WTC_000131213 SciLab Job#: 201093155 Client Name: Hillmann Environmental Company, Inc. a Table I Summary of Bulk Asbestos Analysis Results 85 West Street, New York, NY £8728 "d 2 eBeg 26E6 629 cle SciLab Client : HG Sample Heat Acid Insoluble Sample Sample# Area Weight Sensitive Soluble Non-Asbestos Asbestos by Asbestos by # Location (gram) Organic % —=—‘ Inorganic % Inorganic % PLM/DS TEM al MM092601 — — Ist Floor, Ray's Restaurant 02 MM092602. — — sae _— 4rd Floor, Kitchen Haitway 03 MMO092603 -—: -—- — _ 4th Floor, Engineering Office 04 MM092604 = — —— a 4th Floor, Carpentry Shop 05 MM092605 aes --- —- 4th Floor, Electric Room 06 6©MM092606 oo = — 3rd Floor, Kitchen , NVA NA NVA NA NVA NA STequsewvoesraAuyQ UuuewTCTH «- Z6E6 GLO Z2tz Séy71 DJISILN3IOS Analyzed by: Jonathan Teda, ; Date Analyzed: 9/26/2001 *NAD/NSD = no asbestos detected; NA = notanalyzed; NA/PS = not analyzed / positive stop; PLM Balk Asbestos Analysis by EPA 600/M4-82-020 per 40 CER 763 (NVLAP Lab #200546-0) and BLAP PLM Analysi Protocol 198.1 for New York samples (NYSDOH PBLAP Lab @ 11480), ELAP TEM Analysis Protocol 198.4 far negative NY NOB samples: Note: PLM is nat consistently reliable in detecting asbestos in Moor coverings and similar nov-friable organically bound materials. TEM 1s curently the oaly method that can be used to determine if this material can be consideted or treated as non-agbestos-containing in New York State (also sve EPA Advisory for floor tile, FR 59, 146, 38970, 871/94). National Institute of Standards and Tochnology Accreditation requirements mandate that this report must not be reproduced except in ful) without the approval of the laboratory. This PLM report relates ONLY to. the items tested. Z : ATHA# 102843; VT Cert ALO16055 NVA=No Visible Asbesins 8S:61 Tei vOlG T@Ge-Se-d3s 10/92/6 Reviewed By: TPOATA.eY NYC 9/11 Public Portal Document

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000131213Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →