Comparison of Four Data Sets for Asbestos and Lead Asbestos Lead NYC-WTC 000148576

Microvac Wipe Air Microvac Wipe Statistic Location Air (PCMe) f/cc f/cm2 f/cm2 1g/m3 ug/fť2 ug/ft2 Q.0009 30.000* 30,000* + 25- 25 Clearance Criteria 25.5 NYC 9/11 Public Portal Document

125 Cedar Street 0.00153 0.00103 272,231 37,380 0.27 39.5 18.3 110 Liberty Average 0.000$6 WTC Indoor Dust 0.0004 19,316 17,346 0.286 5.22 3.18 Background 0.0009 10.3 125 Cedar Street Minimum 742 0.055 0.78 5.02 110 Liberty 0.0004 1.600 Detected 0.0004 WTC Indoor Dust Concentration 1,582 1,187 0.058 2.46 0.53 Background 0.0004 93.1 125 Cedar Street 0.0035 Maximum 233,475 0.757 293 51.6 110 Liberty 0.0033 10,967,100 Detected 28.5 WTC Indoor Dust 0.0016 Concentration 0.0004 72.093 149,055 0.513 9.73 49 Background 37/101 125 Cedar Street 31/210 94/102 62/112 25/27 52/99 28/48 Frequency of 110 Liberty 18/98 Detection WTC Indoor Dust n/a 11/156 19/141 2/88 13/204 59/143 Background 3/97 18/210 14/101 125 Cedar Street 7/98 64/102 22/112 0/27 24/99 5/48 Number Above 110 Liberty Criteria WTC Indoor Dust 17/1550 2/156 3/141 0/88 0/204 1/143 Background 0/97

are missing some Note: The data for each study listed above does not represent a complete data set. Each of the studies Therefore , the values listed above are done for comparis on only and do not portion of the data which was collected. for which the compound was represent actual, verified values for the sites. Additionally, the values only represent samples ons using 1/2 of the detected. Thus, the average would be lower when the non-detect samples are included in the calculati Cleanup studies contain detection limit. Also note that the data for 125 Cedar Street, 110 Liberty and the WTC Indoor Dust both pre-cleaning and post-cleaning data.

* Tier 1 criteria from the COPC document. This represents a concentration that requires aggressive cleaning.

1/24/2003 ---- Draft ---

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000148576Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000150106 · Box DEP Box 11

DEP report explaining ambient air monitoring for asbestos and the use of indoor standards to characterize outdoor levels.

Cited alongside this record in an Ask answer

NYC-WTC_000150109 · Box DEP Box 11

Department of Environmental Protection report detailing ambient outdoor air monitoring for asbestos fibers.

Cited alongside this record in an Ask answer

Compare copies and versions →