18 shared non-person entities · Same agency, volume and box · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗Analytical results to FEMA, 114 [address], July 2003
Machine-extracted title · confidence 75%Document with WTC cleanup analytical data and minimum concentration information for 114 [address], transmitted to FEMA.
NYC-WTC_000160455–000160459
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Asbestos Data
Based on the results that were received, it appears that eleven wipe samples and sixteen microvacuum samples were collected by Ambient Group Inc. and analyzed by EMSL Analytical Inc. for asbestos. An additional wipe sample and two microvacuum samples were submitted as blanks. A summary of the results is presented below.
Location Matrix Sample Minimum Average Maximum Size Cone. Cone. Cone. (s/cm^) (s/cm^) (s/em^) Ail locutions MB! _______________ Below floor Wipe I 11,681 11,681
Wall Tracking Wipe 9 8,056 726,108 4,327,650
Below Light Switch Wipe 1 8,652 8,652
Blank Wipe 1 2,164 2,164
■ ills \ Below Floor Microvacuum 10 40,192 369,830 1,115,570
Wall Tracking Microvacuum 1 15,058 15,058
I-beam Micro vacuum 2 7,636 7,636 8,038 (ND)
Column Micro vacuum 1 8,038 (ND) 8,038 (ND)
Pipe Shaft Microvacuum 71,592 71,592
Front Office Microvacuum 1 743,552 743,552
Blank Microvacuum 2 803 803
ND= asbestos not detected
The interpretation of these results is constrained by the scientific uncertainty regarding the potential for the measured concentrations in settled dust to become airborne. There are no standards currently available for assessing potential health consequences from asbestos through the evaluation of wipe or microvacuum samples. A scientific peer review panel (World Trade Center October 21- 22,2002 Peer Review Meeting Notes. Available at www.tera.org.) recently evaluated the technical soundness of estimating airborne asbestos concentration as a function of asbestos concentration in settled dust for the purpose of setting health-based benchmarks. The panel recommended against such an approach based on the significant uncertainty associated with the numerous factors (such as activity patterns, sample location, surface characteristics, air exchange rates and room
2
NYC-WTC_000160457
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
Filed elsewhere
NYC-WTC_000163186
Correspondence regarding corrections to FEMA documentation, focusing on proper indoor and outdoor wipe sampling procedures for environmental testing.
18 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000163168
EPA correspondence transmitting draft letter to FEMA regarding 114 Liberty with attached documentation and data receipt timeline.
19 shared non-person entities · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000163174
Technical review of mold and bacteria laboratory results and draft assessment for 114 Liberty with recommendations for letter revision.
18 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000151361
A letter defending the validity of DEP and contractor data used to clear residential units at 114 Liberty Street for re-occupancy.
18 shared non-person entities · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155002
Federal agencies respond to resident concerns regarding the validity of environmental clearance data for 114 Liberty Street.
19 shared non-person entities · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000154948
Federal agencies respond to resident concerns regarding the validity of environmental clearance data for 114 Liberty Street.
19 shared non-person entities · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
13 shared non-person entities · 1 shared topics · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149432
DEP asbestos project notification form and inspection report dated December 12, 2002.
11 shared non-person entities · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155264
Letter from EPA official to a Congressional representative criticizing the adequacy of the 114 Liberty Street cleanup.
14 shared non-person entities · 1 shared topics · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000154976
Correspondence criticizing the EPA and DEP regarding asbestos, silica levels, and safety clearance after cleaning at 114 Liberty Street.
14 shared non-person entities · 1 shared topics · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145869
Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.
14 shared non-person entities · 1 shared topics · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Buildings in this record
Machine-extracted building matches; verify each source. Buildings, never households.
- 110 Liberty Street · 1 pages · confidence 0.00 · verify page 4
- 114 Liberty Street · 1 pages · confidence 0.15 · verify page 2
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000163186
Correspondence regarding corrections to FEMA documentation, focusing on proper indoor and outdoor wipe sampling procedures for environmental testing.
Similar indexed content
Similar indexed content
NYC-WTC_000163168
EPA correspondence transmitting draft letter to FEMA regarding 114 Liberty with attached documentation and data receipt timeline.
Similar indexed content
NYC-WTC_000163174
Technical review of mold and bacteria laboratory results and draft assessment for 114 Liberty with recommendations for letter revision.
Similar indexed content
NYC-WTC_000151361
A letter defending the validity of DEP and contractor data used to clear residential units at 114 Liberty Street for re-occupancy.
Similar indexed content