18 shared non-person entities · Same agency, volume and box · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗Analytical results to FEMA, 114 [address], July 2003
Machine-extracted title · confidence 75%Document with WTC cleanup analytical data and minimum concentration information for 114 [address], transmitted to FEMA.
NYC-WTC_000160455–000160459
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
volume) that influence this relationship. EPA’s use of surface wipe and microvacuum sampling at its WTC Residential Confirmation Cleaning Study site (110 Liberty St.) was intended to provide a measure of cleaning effectiveness, and not a risk-based health assessment. EPA’s WTC Residential Confirmation Cleaning Study can be obtained at http://www.epa.gov/wtc/ .
Primarily, risk from asbestos is directly related to its concentration in air. Consequently, post-cleaning aggressive (i.e., use of a leaf blower and fans) air sampling was conducted at 114 Liberty St. by DEP’s contractors to insure that asbestos levels in air met risk-based clearance criteria.
The EMSL analytical report does not provide detailed information on sample collection; however, it appears many samples were collected from inaccessible areas below the hardwood flooring, or from areas of unknown accessibility such as, wall tracking, pipe shafts and I-beams. The scope of work developed for the clean up activities was designed for the removal of debris from the collapse of the World Trade Center and did not include the removal or remediation of pre-existing building materials. As a matter of precaution, any residual dust and, thus, potential reservoirs of asbestos, from accessible areas should be cleaned using the technique of vacuuming and wet-wiping.
Asbestos containing materials (ACMs), such as floor tiles, were observed during DEP’s cleaning of the building. Some of the ACMs may be present under the hardwood flooring, thus samples collected from this location may be more representative of the building materials contained within the building rather than indicating contamination from other sources. Additionally, DEP noted and reported the presence of thermal system insulation and damaged asbestos-containing fireproofing within the building. Building representatives were provided with this information and were informed of the provisions of Title 15, Chapter 1 of the Rules of the City of New York that require the determination of the presence and quantity of ACM prior to alteration, renovation, modification, or demolition activities.
It should also be noted that several errors were detected in the calculation of sample concentrations. Two samples had incorrect concentrations reported, samples 221160-02 and 221160-03 (reported on page 6 of the report) should have reported concentrations of 1,471,401 and 432,765 s/cm , respectively.
Mold and Bacteria Data
Based upon the results that were received, it appears that one sample was collected for mold and bacteria from a kitchen floor and counter on the third floor. The sample was analyzed by P&K Microbiology Services, Inc. with the number and type of fungi and bacteria being counted and identified. Seven fungi species were identified with the highest count for any one species being 900 colony forming units/square inch (CFU/in^ ) and a total sum of 2,200 CFU/in^, while six bacteria species were identified with the highest count for any one species being 500 CFU/in^ and a total sum of 1,600 CFU/in^.
3
NYC-WTC_000160458
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
Filed elsewhere
NYC-WTC_000163186
Correspondence regarding corrections to FEMA documentation, focusing on proper indoor and outdoor wipe sampling procedures for environmental testing.
18 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000163168
EPA correspondence transmitting draft letter to FEMA regarding 114 Liberty with attached documentation and data receipt timeline.
19 shared non-person entities · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000163174
Technical review of mold and bacteria laboratory results and draft assessment for 114 Liberty with recommendations for letter revision.
18 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000151361
A letter defending the validity of DEP and contractor data used to clear residential units at 114 Liberty Street for re-occupancy.
18 shared non-person entities · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155002
Federal agencies respond to resident concerns regarding the validity of environmental clearance data for 114 Liberty Street.
19 shared non-person entities · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000154948
Federal agencies respond to resident concerns regarding the validity of environmental clearance data for 114 Liberty Street.
19 shared non-person entities · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
13 shared non-person entities · 1 shared topics · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149432
DEP asbestos project notification form and inspection report dated December 12, 2002.
11 shared non-person entities · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155264
Letter from EPA official to a Congressional representative criticizing the adequacy of the 114 Liberty Street cleanup.
14 shared non-person entities · 1 shared topics · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000154976
Correspondence criticizing the EPA and DEP regarding asbestos, silica levels, and safety clearance after cleaning at 114 Liberty Street.
14 shared non-person entities · 1 shared topics · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145869
Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.
14 shared non-person entities · 1 shared topics · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Buildings in this record
Machine-extracted building matches; verify each source. Buildings, never households.
- 110 Liberty Street · 1 pages · confidence 0.00 · verify page 4
- 114 Liberty Street · 1 pages · confidence 0.15 · verify page 2
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000163186
Correspondence regarding corrections to FEMA documentation, focusing on proper indoor and outdoor wipe sampling procedures for environmental testing.
Similar indexed content
Similar indexed content
NYC-WTC_000163168
EPA correspondence transmitting draft letter to FEMA regarding 114 Liberty with attached documentation and data receipt timeline.
Similar indexed content
NYC-WTC_000163174
Technical review of mold and bacteria laboratory results and draft assessment for 114 Liberty with recommendations for letter revision.
Similar indexed content
NYC-WTC_000151361
A letter defending the validity of DEP and contractor data used to clear residential units at 114 Liberty Street for re-occupancy.
Similar indexed content