City of New York that require the determination of the presence and quantity of ACM prior to alteration, renovation, modification, or demolition activities.

It should also be noted that several errors were detected in the calculation of sample concentrations. Two samples had incorrect concentrations reported, samples 221160-02 and 221160-03 (reported on page 6 of the report) should have reported concentrations of 1,471,401 and 432,765 s/cm^, respectively.

Mold and Bacteria Data

Based upon the results that were received, it appears that one sample was collected for mold and bacteria from a kitchen floor and counter on the third floor. The sample was analyzed by P&K Microbiology Services, Inc. with the number and type of fungi and bacteria being counted and identified. Seven fungi species were identified with the highest count for any one species being 900 colony forming units/square inch (CFU/in') and a total sum of 2,200 Cl47in ’. while six bacteria species were identified with the highest count for any one species being 500 CFU/in^ and a total sum of 1,600 CFU/inC

Mold

Interpretation of these results cannot be completed using standard practices. The standard practice for determining if an indoor environment is being impacted by mold is to compare the species and concentration of indoor mold samples to outdoor mold samples that were collected during the same sampling event. However, based on the data received, it appears that there were no outdoor samples collected for comparison. Using an approach that is less desired than the standard practice, the following conclusions can be drawn from the data. Although there are no specific standards, the general rule of thumb for interpreting mold data usually considers concentrations greater than 10,000 CFU/in^ to be the low end of the spectrum for beginning additional mold investigation, and concentrations greater than 100,000 to signify “mold contamination”. The concentrations for each individual species, as well as the total sum for all species was well below 10,000 CTl Vin ’. In addition, the fungi species observed are the most frequent species identified and are ubiquitous in the environment, both outdoors and indoors. This leads to an overall conclusion that the concentration and species of mold present are typical of an indoor environment. More information can be obtained from the American Industrial Hygiene Association at http://www.ailia.org/CjovernnientAffairs-PR/litml/oomold.htm.

4

CITY_21MC100_003211264

NYC-WTC_000234525

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000234525Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →