City of New York that require the determination of the presence and quantity of ACM prior to alteration, renovation, modification, or demolition activities.

It should also be noted that several errors were detected in the calculation of sample concentrations. Two samples had incorrect concentrations reported, samples 221160-02 and 221160-03 (reported on page 6 of the report) should have reported concentrations of 1,471,401 and 432,765 s/cm^, respectively.

Mold and Bacteria Data

Based upon the results that were received, one wipe sample was collected for mold and bacteria from a kitchen floor on the third floor of the building. The sample was analyzed by P&K Microbiology Services, Inc. with the number and type of fungi and bacteria being counted and identified. Seven fungi species were identified with the highest count for any one species being 900 colony forming units/square inch (CFU/in') and a total sum of 2,200 CFU/in^, while six bacteria species were identified with the highest count for any one species being 500 CFU/in^ and a total sum of 1,600 CFU/itf.

Mold

Although there are no specific standards, a general rule of thumb for interpreting mold data considers concentrations less than 10,000 CFU/in^ to be low and typical of background levels The concentrations for each individual species, as well as the total sum for all species was well below 10,000 CFU/in^ and should be considered background levels. In addition, the dominant fungi that were observed are commonly identified species and are ubiquitous in the environment, both indoors and outdoors .

Bacteria

As with mold, there are no standards for comparison. However, one report (http://www.atsdr.cdc.gov/HAC/PHA/franklinfungi/ief pl.html) from the Agency for Toxic Substances and Disease Registry (ATSDR) states that concentrations of Bacillus at 1,000 CFU/in^ and Staphylococcus at 2,400 CFU/in^ are low and most likely are a normal part of the bacterial load. The concentrations reported from 114 Liberty are much lower than these values and should be considered background levels. In addition, the dominant species found was Staphylococcus, a common human associated bacterium.

If you have any questions related to health-based benchmarks, please contact Dr. Mark Maddaloni of EPA at (212) 637-3590. If you have any

4

CITY_21MC100_004992306

NYC-WTC_000233998

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000233998Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →