...... 9/12 - 10/4. Attachment ] WORLD TRADE CENTER "AIR MONITORING TABLE Fiber Asbestos Duration : Sample PCM .... Conc Conc TEM Date Ambient!" Sampled Volume LOQ PCM rocution Sampled Indoor (Mins) (liters) (t/cc) (f/cc) (struc./mm2) Straple ID PERIMETER SAMPLES 95 950 overload NYC-WTC 000148581

09/12/01 10912/A207001 GREENWICH & CHAMBERS ST. AMBIENT 0.080 10912/A207002 CENTRE & CHAMBERS ST. AMBIENT 90 900 0.016 123.73 09/12/01 AMBIENT 95 950 0.040 157.48 09/12/01 10912/A207003 SPRUCE & GOLD ST BROADWAY & WORTH ST AMBIENT 50 500 0.010 44.99 09/12/01 10912/A207004 09/12/01 10912/A207005 W.BROADWAY & WORTH ST AMBIENT 35 350 0.010 11.25 NYC 9/11 Public Portal Document

PERIMETER SAMPLES 09/13/01 10913/A207001 MURRAY & CHURCH ST. AMBIENT 25 375 0.220 overload 09/13/01 10913/A207002 FULTON & CHURCH ST. AMBIENT 40 600 0.100 overload MURRAY & GREENWICH ST. AMBIENT 40 600 0.008 09/13/01 10913/A207003 <LOQ LIBERTY & CHURCH ST. AMBIENT 30 450 0.01 <LOQ 09/13/01 10913/A207005 WASHINGTON & CEDAR ST. AMBIENT 30 450 0.01 <LOQ 09/13/01 10913/A207004

PERIMETER SAMPLES 10914/A003001 MURRAY & CHURCH ST. AMBIENT 40 600 0.008 <LOQ 09/14/01 10914/A003002 FULTON & CHURCH ST. AMBIENT 40 600 0.007 09/14/01 09/14/01 10914/A003007 MURRAY & GREENWICH ST. AMBIENT 50 750 0.006 <LOQ 09/14/01 10914/A003003 LIBERTY & CHURCH ST. AMBIENT 40 600 0.020 14.32 09/14/01 10914/A003004 CEDAR & TRINTY PL AMBIENT 39 585 0.027 overload 09/14/01 10914/A003008 MURRAY BETWEEN CHURCH & BROADWAY AMBIENT 40 600 0.002 09/14/01 10914/A003009 FULTON BETWEEN CHURCH & BROADWAY AMBIENT 30 450 0.01 <LOQ HOT ZONE SAMPLES 10914/A003005 AMBIENT 50 750 0.007 <LOQ 09/14/01 1 LIBERTY PLAZA - APPROX. 50 FT FROM EXPLOSION AMBIENT 35 525 0.009 <6.56 09/14/01 10914/A003006 PARK & GREENWICH ST .- APPROX. 50 FT. FROM EXPLOSION DEP FACILITY INDOOR 65 975 0.005 09/14/01 10914/A207006 184 AVE D, DEP PUMPING STATION - FOUR BAY AREA

PERIMETER SAMPLES 09/15/01 MURRAY & CHURCH ST. AMBIENT 35 525 0.022 120.18 10915/A307001 302-1 FULTON & CHURCH ST. AMBIENT 40 600 0.034 overload 09/15/01 09/15/01 LAB3#2 MURRAY & GREENWICH ST. AMBIENT 45 675 0.031 overload AMBIENT 50 750 0.008 overload 09/15/01 LABI#2 LIBERTY & BROADWAY 09/15/01 LAB3#3 CEDAR & BROADWAY AMBIENT 30 450 0.033 overload 09/15/01 10915/A307003 BROADWAY & MURRAY ST' AMBIENT 30 450 0.045 overload 09/15/01 10915/A307002 MURRAY BETWEEN CHURCH & BROADWAY AMBIENT 50 750 0.024 overload LABI#1 FULTON BETWEEN CHURCH & BROADWAY AMBIENT 45 675 0.035 131.23 09/15/01 HOT ZONE SAMPLES LAB3#1 GREENWICH & PARK PL AMBIENT 30 450 0.076 overload 09/15/01

METHODS: 1. PCM : NIOSH 7400 METHOD, "A" COUNTING RULE. 2. TEM : EPA 40 CFR PART 763 FINAL RULE (AHERA) Page 1 of 12

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000148581Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000150106 · Box DEP Box 11

DEP report explaining ambient air monitoring for asbestos and the use of indoor standards to characterize outdoor levels.

Cited alongside this record in an Ask answer

NYC-WTC_000150109 · Box DEP Box 11

Department of Environmental Protection report detailing ambient outdoor air monitoring for asbestos fibers.

Cited alongside this record in an Ask answer

Compare copies and versions →