NYC 9/11 Public Portal Document
Air Monitoring in Lower Manhattan Page 3 of 3
School Monitoring Data
DEP worked with the involved City agencies, including the Board of Education, to
provide air monitoring in and around the schools near the World Trade Center
disaster site. DEP collected 8 hour ambient air samples that were analyzed for
asbestos at four locations. These locations were outside of the main entrances to:
Stuyvesant High School, IS/PS 89, PS 234 and the High School of Economics and
Finance. DEP began sampling on October 4, 2001, and completed sampling on
June 30, 2002. From October 4th through October 18th, DEP only did a TEM
analysis if the PCM concentration was above 0.01 fibers per cubic centimeter
(f/cc). During this period of time, there was only one reading above 0.01 f/cc. The
TEM result was below the Asbestos Hazard Emergency Response Act (AHERA)
standard of 70 structures per square millimeter (s/sqmm). As of October 19, 2002,
DEP began conducting a TEM analysis on all samples to provide a direct
comparison to the AHERA standard. Between October 19 and June 30, 2002, all
samples were well below the AHERA standard of 70 s/sqmm.
School Monitoring Data
Additonal Information
· Advisory for Building Façade Clean-up
· Notice to Building Owners Located South of 14th Street. Manhattan:
Building Maintenance Issues Involved in Reopening Buildings Closed Since
9/11/01
. New York City Department of Health Responds to the World Trade Center
Disaster
· New York City Department of Health Asbestos Fact Sheet
Last updated January 3, 2003
Air, Noise and Hazardous Materials
DEP · Air monitoring in Lower Manahattan
· Certified Asbestos Investigators, Contractors and Firms
· Asbestos Rules and Regulations
· Asbestos Abatement Activity Forms
About DEP | Help Center | Education Information | DEP News | Contact Us | DEP Homepage!
Go to NYC.gov Home Page
Mayor's Office | City Agencies | Services | News & Features | City Life | Contact Us | Search
http://www.nyc.gov/html/dep/html/airmonit.html 8/13/2003
NYC-WTC_000148559
OCR can misread numbers and units. Confirm readings against the page image before using them.